E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:36 Uhr
Seite 33
Electrical Conduits
e
mm a r g o r EN P
Edition II/1
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:34 Uhr
Seite 2
Economical and Environmentally Sound Pipe Systems Made of Thermoplastic Materials
HEGLER PLASTIK GMBH Heglerstraße 8 D-97714 Oerlenbach/Unterfranken Phone: ++49 (0) 97 25 66-0 Fax: ++49 (0) 97 25 66-115
Production and marketing of pipe systems and extruder downstream equipment, R & D centre, head office
Structural Engineering, Building Construction and Industrial Construction • conduit systems consisting of pliable plastic pipes • conduit systems consisting of rigid plastic pipes for surface wiring • conduit systems meeting highest fire protection requirements • pliable and rigid conduit systems made of steel and aluminium for industrial installations
Civil Engineering • waste water sewer pipe systems • storm water sewer pipe systems • drainage pipe systems for the protection of structures • inspection manholes for subsoil drainage systems • seepage systems for preclarified waste water and storm water • drainage pipes for road construction and civil engineering purposes • cable ducting systems for underground installation
Special Applications • flexible corrugated protective tubes for sanitary and heating engineering • flexible and rigid tubes made of engineering plastics to be used for example in machine and apparatus construction, automotive industry and medical engineering
Agricultural Drainage • flexible drainage pipes • heating pipes for horticulture
Special machine construction • extruder downstream equipment to produce corrugated and twin wall pipes for a great variety of applications
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:34 Uhr
Seite 3
Contents ELECTRICAL CONDUITS HEGLERFLEX pliable electrical conduits
pages 4 - 7
HEGLERPLAST smooth rigid electrical conduits
pages 8 - 9
STAPAFLEX pliable armoured conduits made of steel STAPA smooth rigid armoured conduits made of steel HEGLER-ALU smooth rigid conduits made of aluminium
page 10 pages 12 - 13 page 14
Accessories for ELECTRICAL CONDUITS HEGLERFLEX/HEGLERPLAST
page 16
STAPAFLEX/STAPA
page 17
HEGLER-ALU
page 18
HEKAPLAST structured-walled cable ducts made of PE-HD
page 20
HEKAPLAN/HEKAWELL structured-walled cable ducts made of PVC-U
page 21
HEKAPLAST
page 22
HEKAPLAN
page 23
HEKAWELL
page 24
CABLE DUCTS
Accessories for CABLE DUCTS
CLASSIFICATION
page 26
NOMINAL DIAMETERS
page 27
SYNOPTICAL TABLE
pages 28 - 29
3
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:34 Uhr
Seite 4
HEGLERFLEX pliable electrical conduits Due to their special corrugated shape and constant quality, HEGLERFLEX electrical conduits meet all requirements to allow easy and progressive installation. The product is available in a great variety of stiffnesses, raw
materials and mechanical properties to suit the different requirements resulting from the way of construction and degree of loading.
HEGLERFLEX-EYL 2 2 4 3 2
strength: light (320 N) impact: light lower temperature range: -25 °C upper temperature range: 105 °C pliable
HEGLERFLEX-EYL
Raw material: PE/PP (halogen-free) Colour: orange Application: for surface and concealed wiring as well as for installation in precast concrete
DIN EN 50086-2-2: classification 22432
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Coil length Item No.
16
20
25
32
40
50
63
≥10.5
≥13.5
≥17.4
≥23.5
≥30.1
≥37.7
≥50.1
(m)
100
100
50
50
25
25
25
93000..
16
20
25
32
40
50
63
Accessories
grooved couplers, see page 16
HEGLERFLEX-EYLF 2 2 3 2 2
strength: light (320 N) impact: light lower temperature range: -15 °C upper temperature range: 90 °C pliable
HEGLERFLEX-EYLF
DIN EN 50086-2-2: classification 22322
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Coil length Item No. Accessories 4
Raw material: PE/PP (flame-retardant) Colour: black with and without coloured marking stripes Application: for surface and concealed wiring as well as for installation in precast concrete, cavities and false floors
16
20
25
32
40
50
63
≥10.5
≥13.5
≥17.4
≥23.5
≥30.1
≥37.7
≥50.1
(m)
100
100
50
50
25
25
25
93100..
16
20
25
32
40
50
63
grooved couplers, see page 16
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:34 Uhr
Seite 5
HEGLERFLEX-EL 2 2 2 1 2
strength: light (320 N) impact: light lower temperature range: -5 °C upper temperature range: 60 °C pliable
HEGLERFLEX-EL
Raw material: PVC-U (flame-retardant) Colour: white (acc. to RAL 1013) Application: for surface and concealed wiring as well as for installation in cavities and false floors
DIN EN 50086-2-2: classification 22212
Nominal diameter
DN
16
20
25
32
40
50
63
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
≥10.7
≥14.1
≥18.3
≥24.3
≥31.2
≥39.6
≥50.6
(m)
100
100
50
50
25
25
25
92000..
16
20
25
32
40
50
63
Coil length Item No. Accessories
grooved couplers, see page 16
HEGLERFLEX-ESPM 3 3 2 1 2
strength: medium (750 N) impact: medium lower temperature range: -5 °C upper temperature range: 60 °C pliable
HEGLERFLEX-ESPM
Raw material: PVC-U/P (flame-retardant) Colour: grey (acc. to RAL 7035) Application: for installation in vibrated, heaped and tamped concrete as well as in floor finish
DIN EN 50086-2-2: classification 33212
Nominal diameter
DN
16
20
25
32
40
50
63
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
≥10.7
≥13.0
≥16.9
≥21.4
≥31.2
≥39.6
≥50.6
(m)
50
50
50
25
25
25
25
92300..
16
20
25
32
40
50
63
Coil length Item No. Accessories
smooth couplers, see page 16
HEGLERFLEX-ESPM 105 3 3 3 3 3
strength: medium (750 N) impact: medium lower temperature range: -15 °C upper temperature range: 105 °C self-recovering
HEGLERFLEX-ESPM 105
Raw material: special thermoplastic material (flame-retardant) Colour: reddish brown Application: for installation in vibrated, heaped and tamped concrete as well as in floor finish where high resistance to thermal deformation is required
DIN EN 50086-2-2: classification 33333
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Coil length Item No. Accessories
16
20
25
32
40
50
63
≥10.5
≥13.5
≥17.4
≥23.5
≥30.1
≥37.7
≥50.1
(m)
50
50
50
25
25
25
25
92500..
16
20
25
32
40
50
63
grooved couplers, see page 16 5
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:34 Uhr
Seite 6
HEGLERFLEX-ESPS 4 3 2 1 2
strength: heavy (1250 N) impact: medium lower temperature range: -5 °C upper temperature range: 60 °C pliable
HEGLERFLEX-ESPS
Raw material: PVC-U/P (flame-retardant) Colour: black Application: for installation in vibrated, heaped and tamped concrete as well as in floor finish and for all applications requiring high compression strength
DIN EN 50086-2-2: classification 43212
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Coil length Item No.
16
20
25
32
40
50
63
≥10.7
≥13.0
≥16.9
≥21.4
≥31.2
≥39.6
≥50.6
(m)
50
50
50
25
25
25
25
92400..
16
20
25
32
40
50
63
Accessories
smooth couplers, see page 16
HEGLERFLEX-ELH 2 3 2 3 2
strength: light (320 N) impact: medium lower temperature range: -5 °C upper temperature range: 105 °C pliable
HEGLERFLEX-ELH
Raw material: PP mod (halogen free, flame-retardant) Colour: black Application: for concealed and surface wiring as well as for installation in cavities and false floors and precast concrete for applications subject to strict safety regulations
DIN EN 50086-2-2: classification 23232
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Coil length Item No.
16
20
25
32
40
50
63
≥10.5
≥13.5
≥17.4
≥23.5
≥30.1
≥37.7
≥50.1
(m)
100
100
50
50
25
25
25
91000..
16
20
25
32
40
50
63
Accessories
grooved couplers, see page 16
HEGLERFLEX-EYSPMH 3 3 2 3 2
strength: medium (750 N) impact: medium lower temperature range: -5 °C upper temperature range: 105 °C pliable
HEGLERFLEX-EYSPMH
DIN EN 50086-2-2: classification 33232
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm) (m)
50
50
50
25
25
25
25
91200..
16
20
25
32
40
50
63
Coil length Item No. Accessories 6
Raw material: special thermoplastic material (halogen-free, flame-retardant) Colour: black Application: for installation in vibrated, heaped and tamped concrete as well as in floor finish for applications subject to strict safety regulations
16
20
25
32
40
grooved couplers, see page 16
50
63
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:34 Uhr
Seite 7
HEGLERFLEX-EGL 2 2 4 1 2
strength: light (320 N) impact: light lower temperature range: -25 °C upper temperature range: 60 °C pliable
HEGLERFLEX-EGL
Raw material: PE Colour: orange Application: for concealed and surface wiring
DIN EN 50086-2-2: classification 22412
Nominal diameter
DN
16
20
25
32
40
50
63
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
≥10.5
≥13.5
≥17.8
≥23.5
≥30.1
≥37.7
≥50.1
(m)
50
100
50
50
25
25
25
93400..
16
20
25
32
40
50
63
Coil length Item No. Accessories
smooth couplers, see page 16
7
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:34 Uhr
Seite 8
HEGLERPLAST smooth rigid electrical conduits makes an economy-priced installation possible. All rigid HEGLERPLAST pipes are provided with integral conical sockets, which offers further advantages in assembly. HEGLERPLAST conduits are available in a standard length of 3.00 m.
HEGLERPLAST electrical conduits for surface assembly where an impeccable appearance is required. The smooth PVC-U conduits in straight lengths are perfectly suitable for surface and concealed wiring and in concrete construction. Only few fastening points are necessary, which
HEGLERPLAST-EL 2 2 2 1 1
strength: light (320 N) impact: light lower temperature range: -5 °C upper temperature range: 60 °C rigid
HEGLERPLAST-EL
DIN EN 50086-2-1: classification 22211
Nominal diameter
DN
16
20
25
Outside diameter
(mm)
16
20
25
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
Inside diameter
(mm)
≥13.7
≥17.4
≥22.1
(m)
111
111
57
97000..
16
20
25
Contents of bundle Item No.
Raw material: PVC-U (flame-retardant) Colour: grey (acc. to RAL 7035) Application: for surface wiring as well as installation in cavities and false floors
Accessories
bends, couplers, clamps, see page 16
HEGLERPLAST-EPKM 3 3 2 1 1
strength: medium (750 N) impact: medium lower temperature range: -5 °C upper temperature range: 60 °C rigid
HEGLERPLAST-EPKM
DIN EN 50086-2-1: classification 33211
Nominal diameter
DN
16
20
25
32
40
50
63
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
≥13.0
≥16.9
≥21.4
≥27.8
≥35.4
≥44.3
≥55.6
(m)
111
111
57
57
21
21
21
97100..
16
20
25
32
40
50
63
Contents of bundle Item No. Accessories 8
Raw material: PVC-U (flame-retardant) Colour: grey (acc. to RAL 7035) Application: for surface wiring as well as installation in cavities and false floors and in concrete construction
bends, couplers, clamps, see page 16
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:34 Uhr
Seite 9
HEGLERPLAST-EPKS 4 3 2 1 1
strength: heavy (1250 N) impact: medium lower temperature range: -5 °C upper temperature range: 60 °C rigid
HEGLERPLAST-EPKS
Raw material: PVC-U (flame-retardant) Colour: grey (acc. to RAL 7035) Application: for surface wiring as well as for installation in vibrated, heaped and tamped concrete
DIN EN 50086-2-1 classification 43211
Nominal diameter
DN
16
20
25
32
40
50
63
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
≥12.2
≥15.8
≥20.6
≥26.6
≥34.4
≥43.2
≥54.8
(m)
57
57
57
21
21
21
21
97300..
16
20
25
32
40
50
63
Contents of bundle Item No. Accessories
bends, couplers, clamps, see page 16
HEGLERPLAST-EPKMU 3 3 4 1 1
strength: medium (750 N) impact: medium lower temperature range: -25 °C upper temperature range: 60 °C rigid
HEGLERPLAST-EPKMU
Raw material: PVC-U (UV-stabilized, flame-retardant) Colour: white Application: for surface wiring out of doors
DIN EN 50086-2-1: classification 33411
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Contents of bundle Item No.
16
20
25
32
40
50
63
≥13.0
≥16.9
≥21.4
≥27.8
≥35.4
≥44.3
≥55.6
(m)
57
57
57
21
21
21
21
97200..
16
20
25
32
40
50
63
Accessories
bends, couplers, clamps, see page 16
HEGLERPLAST-EPKMH 3 3 4 2 1
strength: medium (750 N) impact: medium lower temperature range: -25 °C upper temperature range: 90 °C rigid
HEGLERPLAST-EPKMH
Raw material: PPO (halogen-free, flame-retardant) Colour: grey (acc. to RAL 7035) Application: for surface wiring as well as for installation in vibrated, heaped and tamped concrete for applications subject to strict safety regulations
DIN EN 50086-2-1: classification 33421
Nominal diameter
DN
16
20
25
32
40
50
63
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
≥13.0
≥16.9
≥21.4
≥27.8
≥35.4
≥44.3
≥55.6
(m)
111
111
57
57
21
21
21
96000..
16
20
25
32
40
50
63
Contents of bundle Item No. Accessories
bends, couplers, clamps, see page 16 9
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
STAPAFLEX pliable armoured conduits made of steel Pliable armoured steel conduits are made of a high-quality lead-coated sheet iron in multi-layer design. Thanks to their narrow grooving, they are extraordinarily flexible. Depending on the type of pipe, there are layers of impregnated paper in between the iron sheet to provide moisture-proof insulation. One pipe
12:34 Uhr
Seite 10
design is covered with a PVC-P coat for protection against corrosion. By this, these pipes offer protection against moisture, aggressive damps and liquids as well as dangerous electricity. All types of armoured steel conduits are suited for high mechanical loads. The pipes without coating are resistant to temperatures of up to 250 °C. They are light in weight and allow economical installation with no need of special tooling or bends. Fixing is easily done by means of clamps. The narrow grooving suits all standardized steel pipe connectors and provides tensile connection. Threading is not necessary.
STAPAFLEX-EP 4 4 5 6 2
strength: heavy (1250 N) impact: heavy lower temperature range: -45 °C upper temperature range: 250 °C pliable
STAPAFLEX-EP
Raw material: lead-coated sheet iron, with layers of insulating paper in between Application: for installation in machine construction, manufacture of apparatus and vehicles as well as in melted asphalt
DIN EN 50086-2-2: classification 44562
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Coil length Item No.
16
20
25
32
40
50
63
≥10.7
≥14.1
≥18.3
≥24.3
≥31.2
≥39.6
≥50.6
(m)
25
25
25
25
25
25
25
90000..
16
20
25
32
40
50
63
Accessories
threaded couplers, see page 17
STAPAFLEX-EPY 4 4 4 1 2
strength: heavy (1250 N) impact: heavy lower temperature range: -25 °C upper temperature range: 60 °C pliable
STAPAFLEX-EPY
DIN EN 50086-2-2: classification 44412
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Coil length Item No. Accessories 10
Raw material: lead-coated sheet iron, with layers of insulating paper in between and covered with a plastic coating for protection against corrosion Application: for installation in machine construction and manufacture of apparatus and vehicles
16
20
25
32
40
50
63
≥10.7
≥14.1
≥18.3
≥24.3
≥31.2
≥39.6
≥50.6
(m)
25
25
25
25
25
25
25
90100..
16
20
25
32
40
50
63
threaded couplers, see page 17
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:34 Uhr
Seite 11
ELTEFA show at Stuttgart
11
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 12
STAPA smooth rigid armoured conduits made of steel Armoured steel conduits made of rolled mild steel are suitable for high compression and temperature loads and for highest mechanical demands. STAPA pipes are available in a standard length of 3.00 m.
STAPA-ESs 4 4 5 6 1
strength: heavy (1250 N) impact: heavy lower temperature range: -45 °C upper temperature range: 250 °C rigid
STAPA-ESs
Raw material: mild steel, rolled, bent, high-frequency welded, with stoveenamelling Application: for applications where high temperatures occur and highest mechanical protection is required
DIN EN 50086-2-1: classification 44561
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Contents of bundle Item No.
16
20
25
32
40
50
63
≥14.0
≥18.0
≥22.6
≥30.6
≥37.6
≥47.6
≥60.0
(m)
30
30
30
21
15
15
15
95000..
16
20
25
32
40
50
63
Accessories
bends, couplers, see page 17
STAPA-EGs 5 5 5 6 1
strength: very heavy (4000 N) impact: very heavy lower temperature range: -45 °C upper temperature range: 250 °C rigid
STAPA-EGs
DIN EN 50086-2-1: classification 55561
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Contents of bundle Item No. Accessories 12
Raw material: mild steel, rolled, bent, high-frequency welded, with stoveenamelling Application: for applications where high temperatures occur and highest mechanical protection is required
16
20
25
32
40
50
63
≥13.0
≥16.8
≥21.8
≥28.8
≥36.8
≥46.8
≥59.4
(m)
30
30
30
21
15
15
15
95100..
16
20
25
32
40
50
63
threaded bends, threaded couplers, see page 17
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 13
STAPA-ESv 4 4 5 7 1
strength: heavy (1250 N) impact: heavy lower temperature range: -45 °C upper temperature range: 400 °C rigid
STAPA-ESv
Raw material: mild steel, rolled, bent, high-frequency welded and galvanized Application: for all applications where high temperatures occur and highest mechanical protection and corrosion resistance are required
DIN EN 50086-2-1: classification 44571
Nominal diameter
DN
16
20
25
32
40
50
63
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
≥14.0
≥18.0
≥22.6
≥30.6
≥37.6
≥47.6
≥60.0
(m)
30
30
30
21
15
15
15
95001..
16
20
25
32
40
50
63
Contents of bundle Item No. Accessories
bends, couplers, see page 17
STAPA-EGv 5 5 5 7 1
strength: very heavy (4000 N) impact: very heavy lower temperature range: -45 °C upper temperature range: 400 °C rigid
STAPA-EGv
Raw material: mild steel, rolled, bent, high-frequency welded and galvanized Application: for applications where high temperatures occur and highest mechanical protection and corrosion resistance are required
DIN EN 50086-2-1: classification 55571
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Contents of bundle Item No. Accessories
16
20
25
32
40
50
63
≥13.0
≥16.8
≥21.8
≥28.8
≥36.8
≥46.8
≥59.4
(m)
30
30
30
21
15
15
15
95101..
16
20
25
32
40
50
63
threaded bends, threaded couplers, see page 17
13
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 14
HEGLER-ALU smooth rigid conduits made of aluminium Aluminium conduits for highest mechanical requirements, easy to install and corrosion resistant.
HEGLER ALU-ES 4 4 5 6 1
strength: heavy (1250 N) impact: heavy lower temperature range: -45 °C upper temperature range: 250 °C rigid
HEGLER ALU-ES
Raw material: aluminium Application: for applications where aggressive conditions affect the product, e. g. chemical industry, ship construction etc.
DIN EN 50086-2-1: classification 44561
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Contents of bundle Item No.
16
20
25
32
40
50
63
≥14.0
≥18.0
≥22.6
≥29.2
≥37.2
≥47.0
≥59.4
(m)
30
30
30
30
15
15
15
95200..
16
20
25
32
40
50
63
Accessories
bends, couplers, clamps, see page 18
HEGLER ALU-EG* 5 5 5 6 1
strength: very heavy (4000 N) impact: very heavy lower temperature range: -45 °C upper temperature range: 250 °C rigid
HEGLER ALU-EG
DIN EN 50086-2-1: classification 55561
Nominal diameter
DN
Outside diameter
(mm)
16
20
25
32
40
50
63
Permissible tolerances
(mm)
0/-0.3
0/-0.3
0/-0.4
0/-0.4
0/-0.4
0/-0.5
0/-0.6
Inside diameter
(mm)
Contents of bundle Item No. Accessories 14
Raw material: aluminium Application: for applications where aggressive conditions affect the product, e. g. chemical industry, ship construction etc.
* in preparation
16
20
25
32
40
50
63
≥12.7
≥16.5
≥21.5
≥28.4
≥36.2
≥46.2
≥58.8
(m)
30
30
30
30
15
15
15
95300..
16
20
25
32
40
50
63
threaded bends, threaded couplers, clamps, see page 18
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 15
Light + Building show at Frankfurt
15
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 16
Accessories: HEGLERFLEX and HEGLERPLAST Grooved coupler grey for HEGLERFLEX-EL, black for HEGLERFLEX-EYL, EYLF, ESMP 105, ELH and EYSMPH
Bend belled at one end, grey, of PVC-U for HEGLERPLASTEPKM and EPKS, of PPO for HEGLERPLAST-EPKMH
16
DN
16
20
25
32
40
50
63
(pcs.)
100
100
50
50
25
25
10
98600..
16
20
25
32
40
50
63
EYL, EYLF, ESPM 105, ELH, EYSPMH Item No. 98700..
16
20
25
32
40
50
63
Bag quantity EL Item No.
DN
16
20
25
32
40
50
63
(pcs.)
50
50
50
50
10
10
10
EPKM, EPKS Item No.
98110..
16
20
25
32
40
50
63
EPKMH Item No.
98410..
16
20
25
32
40
50
63
16
20
25
32
40
50
63
(pcs.)
100
100
50
50
25
25
10
EPKM, EPKS, ESPM, ESPS, EGL Item No. 98100..
16
20
25
32
40
50
63
EPKMH Item No.
16
20
25
32
40
50
63
16
20
25
32
40
50
63
Bag quantity
Smooth coupler with inside locking cam, grey, of PVC-U for HEGLERPLASTEPKM and EPKS as well as HEGLERFLEXESPM, ESPS and EGL, of PPO for HEGLERPLASTEPKMH
DN
Bend belled at one end, grey, of PVC-U for HEGLERPLAST-EL and black, of special thermoplastic material for HEGLERPLASTEPKMU
DN
Smooth coupler with inside locking cam, grey, of PVC-U for HEGLERPLASTEL and black, of special thermoplastic material for HEGLERPLAST-EPKMU
DN
Clamps suitable for stringing, grey for HEGLERPLAST-EPKM, EPKS, EL; of PPO for HEGLERPLASTEPKMH and black,of special thermoplastic material for HEGLERPLAST-EPKMU
DN
Bag quantity
Bag quantity
98400..
(pcs.)
50
50
50
50
10
10
10
EL Item No.
98010..
16
20
25
32
40
50
63
EPKMU Item No.
98111..
16
20
25
32
40
50
63
16
20
25
32
40
50
63
(pcs.)
100
100
50
50
25
25
10
EL Item No.
98000..
16
20
25
32
40
50
63
EPKMU Item No.
98101..
16
20
25
32
40
50
63
16
20
25
32
40
50
63
Bag quantity
Bag quantity
(pcs.)
100
100
100
50
25
25
10
EPKM, EPKS, EL Item No.
98120..
16
20
25
32
40
50
63
EPKMH Item No.
98420..
16
20
25
32
40
50
63
EPKMU Item No.
98121..
16
20
25
32
40
50
63
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 17
Accessories: STAPAFLEX and STAPA Coupler threaded, for pliable and rigid armoured steel conduits STAPAFLEX-EP, EPY and STAPA-EGs and EGv
Coupler push-fit type, for rigid armoured steel conduits STAPA-ESs and ESv
Bend threaded, for rigid armoured steel conduits STAPA-EGs and EGv
Bend push-fit type, for rigid armoured steel conduits STAPA-ESs and ESv
DN
16
20
25
32
40
50
63
(pcs.)
25
50
50
50
25
10
5
EP, EPY, EGs Item No.
99700..
16
20
25
32
40
50
63
EP, EPY, EGv Item No.
99701..
16
20
25
32
40
50
63
16
20
25
32
40
50
63
(pcs.)
25
50
50
50
25
10
5
ESs Item No.
99800..
16
20
25
32
40
50
63
ESv Item No.
99801..
16
20
25
32
40
50
63
16
20
25
32
40
50
63
(pcs.)
15
25
25
20
15
5
3
EGs Item No.
99710..
16
20
25
32
40
50
63
EGv Item No.
99711..
16
20
25
32
40
50
63
16
20
25
32
40
50
63
Bag quantity
DN Bag quantity
DN Bag quantity
DN Bag quantity
(pcs.)
15
25
25
20
15
5
3
ESs Item No.
99810..
16
20
25
32
40
50
63
ESv Item No.
99811..
16
20
25
32
40
50
63
17
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 18
Accessories: HEGLER-ALU Coupler threaded, for aluminium conduits ALU-EG
DN Bag quantity Item No.
Coupler push-fit type, for aluminium conduits ALUES
Bend threaded, for aluminium conduits ALU-EG
16
20
25
32
40
50
63
(pcs.)
50
50
50
50
25
20
20
99500..
16
20
25
32
40
50
63
16
20
25
32
40
50
63
(pcs.)
50
50
50
50
20
20
20
99600..
16
20
25
32
40
50
63
16
20
25
32
40
50
63
(pcs.)
10
10
10
10
10
10
10
99510..
16
20
25
32
40
50
63
16
20
25
32
40
50
63
(pcs.)
10
10
10
10
10
10
10
99610..
16
20
25
32
40
50
63
16
20
25
32
40
50
63
DN Bag quantity Item No.
DN Bag quantity Item No.
Bend push-fit type, for aluminium conduits ALUES
DN
Clamp for aluminium conduits ALU-EG and ALU-ES
DN
Bag quantity Item No.
Bag quantity Item No.
(pcs.)
50
50
50
50
20
20
20
99620..
16
20
25
32
40
50
63
16
20
25
32
40
50
63
(pcs.)
50
50
50
25
20
20
20
99621..
16
20
25
32
40
50
63
DN Bolted clamp for aluminium conduits ALU-EG and ALU-ES
18
Bag quantity Item No.
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 19
ELTEC show at Nürnberg
19
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 20
HEKAPLAST cable protection and cable ducting pipes It is always a problem to replace or to extend ducting systems under traffic areas, no matter whether in public roads or industrial plants. Digged-up traffic areas handicap activities, annoy local residents, cause considerable costs and leave a ”mended” surface. Cable ducts prevent all this.
They should be installed wherever an increasing need of cables has to be considered.
HEKAPLAST-S Pipe in twin wall design with a corrugated outside and smooth inside; standard length: 6.00 m. Resistant to temperatures from –40 to 105 °C. Raw material: PE Standard colour: black Alternative colours: on request
Quality: a) general purpose grade and b) grade to DIN EN 50086-2-4. Application: as cable duct underground and in concrete; suitable to withstand traffic loads.
HEKAPLAST-S
DN
63
75
90
110
125
140
160
200
Outside diameter
(mm)
63
75
90
110
125
140
160
200
Tolerances
(mm)
+ 1.2
+ 1.4
+ 1.7
+ 2.0
+ 2.3
+ 2.6
+ 2.9
+ 3.6
Inside diameter
(mm)
51.0
62.0
76.0
95.0
107.0
120.5
139.0
173.0
Tolerances
(mm)
Contents of stillage Item No.
± 0.7
± 0.8
± 0.9
± 1.1
± 1.3
± 1.4
± 1.6
± 2.0
(m)
918
1260
720
780
612
360
390
210
7621..
063
075
090
110
125
140
160
200
Accessories
couplers, bends, profiled sealing rings, see page 22
HEKAPLAST-R Pipe in twin wall design with a corrugated outside and smooth inside, with pull wire, pliable. Resistant to temperatures from –40 to 105 °C. Raw material: PE Standard colour: black Alternative colours: on request
HEKAPLAST-R
DN
40
50
63
75
90
110
125
140
160
200
Outside diameter
(mm)
40
50
63
75
90
110
125
140
160
200
Tolerances
(mm)
+ 0.8
+ 1.0
+ 1.2
+ 1.4
+ 1.7
+ 2.0
+ 2.3
+ 2.6
+ 2.9
+ 3.6
Inside diameter
(mm)
32.0
39.5
51.0
62.0
76.0
95.0
107.0
120.5
139.0
173.0
Tolerances
(mm)
± 0.5
± 0.6
± 0.7
± 0.8
± 0.9
± 1.1
± 1.3
± 1.4
± 1.6
± 2.0
Coil length
(m)
50
50
50
50
50
50
50
50
50
50
7629..
004
005
006
007
009
011
013
014
016
020
Item No. Accessories 20
Application: as cable ducts underground and in concrete; suitable to withstand traffic loads. Due to its extraordinary flexibility in longitudinal direction, HEKAPLAST-R is also suitable for difficult cable installations, such as around foundations or other obstacles.
couplers, bends, profiled sealing rings, see page 22
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 21
HEKAPLAN HEKAWELL
Cables often have to be installed in bundles, like in structural engineering, industrial buildings or civil engineering. Protection pipes with integral sockets are a very good option to allow multiple-way ducting in concrete.
HEKAPLAN Pipe in twin wall design, corrugated outside and smooth inside, with integral socket; standard length: 6.00 m. Resistant to temperatures from –5 to 60 °C.
Application: Particularly suited for applications like tunnel or concrete construction in which the pipes are installed in solid bundles and cast in concrete.
Raw material: PVC-U Colour: black
HEKAPLAN
DN
110/100
165/150
Outside diameter
(mm)
110
163
Inside diameter
(mm)
100.5
151.0
Insert depth or depth of coupler
(mm)
100
120
Push-fit coupler/outside diameter (mm)
114
168
Contents of stillage
780
390
110
165
Item No.
(m) 7615..
Accessories
couplers, bends, profiled sealing rings, see page 23
HEKAWELL Flexible corrugated cable duct, compression and impact resistant acc. to DIN 1187. Resistant to temperatures from –5 to 60 °C.
Application: An economy-priced alternative for subordinate jobs and jobs with inferior loading.
Raw material: PVC-U Colour: yellow
HEKAWELL
DN
50
65
80
100
125
160
200
Outside diameter
(mm)
50
65
80
100
125
160
200
Inside diameter
(mm)
44
58
71.5
91
115
144
182
(m)
50
50
50
50
50
50
50
7495..
050
065
080
100
125
160
200
Coil length Item No.
Accessories
see page 24 21
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 22
Accessories: cable ducts HEKAPLAST Coupler with locking cam (w. l. c.) or without locking cam (wo. l. c.), made of PP, black
DN
40
50
63
75
90
110 125 140 160 200
Bag quantity (pcs.)
1
1
1
100
50
75
60
45
36
20
w. l. c. Item No. 7710... 004 005 007 008 009 011 013 014 016 020 wo. l. c. Item No. 7710...
108 109 111 113 114 116 120
Bend 45° r = 1.0 m, shaped from HEKAPLAST pipe, black
DN
75
90
Bag quantity (pcs.)
1
1
Item No. 7710...
208 209 211 213 214 216 220
Bend 90° r = 1.0 m, shaped from HEKAPLAST pipe, black
DN
75
90
Bag quantity (pcs.)
1
1
End cap made of PE, naturalcoloured
DN
40
50
63
75
90
110 125 140 160 200
Bag quantity (pcs.)
50
50
50
50
50
50
Item No. 7710...
110 125 140 160 200 1
1
1
1
1
110 125 140 160 200 1
1
1
1
1
408 409 411 413 414 416 420
50
25
25
25
Item No. 7720... 204 205 207 208 209 211 213 214 216 220
Profiled sealing ring made of elastomeric materials
DN
40
50
63
75
90
110 125 140 160 200
Bag quantity (pcs.) 100 100 100 100 100 200
50
25
25
25
Item No. 7720... 304 305 307 308 309 311 313 314 316 320
Spacer
DN
50
63
75
90
110 125 140 160 200
available in 2-/4-/6-/8-strand version and one- or two-sided version
22
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 23
Accessories: cable ducts HEKAPLAN Coupler made of PVC-U, black
Bend 45° r = 1.0 m, shaped from HEKAPLAN pipe, black
Bend 90° r = 1.0 m, shaped from HEKAPLAN pipe, black
End cap made of PVC-U, black
Profiled sealing ring made of elastomeric materials
DN
110/100
Bag quantity (pcs.)
75
Item No. 7700...
011
DN
165/150 1 015
110/100
165/150
Bag quantity (pcs.)
1
1
Item No. 7701...
011
015
110/100
165/150
Bag quantity (pcs.)
1
1
Item No. 7702...
011
015
DN
DN
110/100
165/150
Bag quantity (pcs.)
1
1
Item No. 7703...
011
015
110/100
165/150
Bag quantity (pcs.)
100
100
Item No. 7704...
011
015
DN
23
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 24
Accessories: cable ducts HEKAWELL Coupler made of PVC-U, yellow
End cap made of PVC-U, black
DN
50
65
80
100
125
160
200
Bag quantity
(pcs.)
100
100
100
50
50
15
10
screw coupler Item No.
7774...
–
–
–
010
012
016
020
sleeve Item No.
7774...
005
006
008
–
–
–
–
50
65
80
100
125
160
200
DN Bag quantity
(pcs.)
200
100
100
100
50
50
1
Item No.
7774...
105
106
108
110
112
116
120
60
80
100
(m) 1000 1000 1000 500
500
Accessories: cover hoods and plates HEKADUKT HRH round hoods with suspension fastening
Type (width in mm) Bag quantity Item No.
PL cover plates
7611...
DN Bag quantity Item No.
24
40
50
040
050
120
180
(m) 1000 1000 7612...
120
180
060
080
100
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 25
25
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 26
Classification To allow the European countries to "grow together", impediments to trade are to be reduced. The harmonisation of national standards into international ones (CEN and CENELEC) comes up to this political request.
No. of DIN standard
In the field of electrical conduits, several standards have been prepared by CENELEC in order to guarantee a uniform product quality in Europe. So there are now standardized nominal diameter series instead of nominal diameters differing from country to country.
In contrast to the so far inch system, these diameters are based on metric measurements. Nominal diameters are now based on the outside diameters and correspond to the following DN series: DN 16, DN 20, DN 25, DN 32, DN 40, DN 50 and DN 63. The following table shows the system of the new standards:
Title
DIN EN 50086-1
Conduit Systems for Electrical Installations Part 1: General Requirements
DIN EN 50086-2-1
Conduit Systems for Electrical Installations Part 2-1: Particular Requirements for Rigid Conduit Systems
DIN EN 50086-2-2
Conduit Systems for Electrical Installations Part 2-2: Particular Requirements for Pliable Conduit Systems
DIN EN 50086-2-3
Conduit Systems for Electrical Installations Part 2-3: Particular Requirements for Flexible Conduit Systems
DIN EN 50086-2-4
Conduit Systems for Electrical Installations Part 2-4: Particular Requirements for Conduit Systems Buried Underground
DIN EN 60423
Electrical conduits Outside Diameters of Electrical conduits and Threads for Electrical conduits and Their Accessories
The new standards also include different specifications regarding designation and marking. The letters
have been turned into a numerical code, the meaning of which can be taken from the following table.
Classification Code for Properties Claimed for a Conduit System Marking of pipe, code No.:
2
2
2
1
2
Example: light weight pipe with light impact resistance, temperature resistant from –5 °C up to +60 °C, non-flame propagating. 5th figure – resistance to bending
1st figure – resistance to compression 1
very light
compression force
125 N
1
rigid
acc. to EN 50086-2-1
2
pliable
acc. to EN 50086-2-2
2
light
compression force
320 N
3
medium
compression force
750 N
3
pliable, self-recovering EN 50086-2-2
4
flexible
4
heavy
compression force
1250 N
5
very heavy
compression force
4000 N
4th figure – upper temperature range 1
2nd figure – resistance to impact 1
very light
falling energy 0.5 kg/100 mm
2
light
falling energy 1.0 kg/100 mm
3
medium
falling energy 2.0 kg/100 mm
4
heavy
falling energy 2.0 kg/300 mm
5
very heavy
falling energy 6.8 kg/300 mm
3rd figure – lower temperature range
26
acc. to EN 50086-2-3
60 °C
transport, perm. application, installation
2
90 °C
transport, perm. application, installation
3
105 °C
transport, perm. application, installation
4
120 °C
transport, perm. application, installation
5
150 °C
transport, perm. application, installation
6
250 °C
transport, perm. application, installation
7
400 °C
transport, perm. application, installation
Colour of pipe Resistance to flame propagation
1
+ 5 °C
transport, perm. application, installation
orange
2
– 5 °C
transport, perm. application, installation
3
–15 °C
transport, perm. application, installation
4
–25 °C
transport, perm. application, installation
5
–45 °C
transport, perm. application, installation
any colour apart from orange, yellow and red
flame propagating non-flame propagating
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 27
Nominal Diameters The new DIN EN 50086-1 In the new EN standard, nominal diameters (DN) are defined differently! The new nominal diameters refer to the real outside diameters. For exam-
ple, a pipe defined as DN 25 now has an outside diameter of 25 mm, while previously the nominal diameters referred to inside diameters.
The table below shows how the new nominal diameters (DN) compare with the previous nominal diameters (DN)
New nominal diameters as per EN
63 50 40 32 25 20 16 DN
9
11
13,5
16
19
21/23
29
36
42
48
Previous definition of types (previous nominal diameters)
27
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 28
Product Range, Product Data and Applications
Product group
Short description of product
HEGLERFLEX electrical conduit, pliable, corrugated, pliable electrical for light duty conduits electrical conduit, pliable, corrugated, for light duty, flame-retardant
Pipe geometry
Standard/ test regulations
PE/PP
corrugated
DIN EN 50086-2-2/ VDE 0605 Teil 2-2
HEGLERFLEXEYLF
16 - 63
black
PE/PP mod
corrugated
DIN EN 50086-2-2/ VDE 0605 Teil 2-2
electrical conduit, pliable, corrugated, for light duty, flame-retardant
HEGLERFLEX-EL
16 - 63
RAL 1013 PVC-U white
corrugated
DIN EN 50086-2-2/ VDE 0605 Teil 2-2
electrical conduit, pliable, corrugated, for medium duty, flame-retardant
HEGLERFLEXESPM
16 - 63
RAL 7035 PVC-U with grey PVC-P coat
corrugated ins. DIN EN 50086-2-2/ smooth outs. VDE 0605 Teil 2-2
electrical conduit, self-recovering, corrugated, for medium duty, flame-retardant
HEGLERFLEXESPM 105
16 - 63
reddish brown
special thermo- corrugated plastic material
electrical conduit, pliable, corrugated, for heavy duty, flame-retardant
HEGLERFLEXESPS
16 - 63
black
PVC-U with PVC-P coat
electrical conduit, pliable, corrugated, for light duty, halogen-free, flame-retardant
HEGLERFLEX-ELH 16 - 63
RAL 7035 PP mod grey
electrical conduit, pliable, corrugated, for medium duty, halogen-free, flame-retardant
HEGLERFLEXEYSPMH
black
special thermo- corrugated ins. DIN EN 50086-2-2/ plastic material smooth outs. VDE 0605 Teil 2-2
electrical conduit, pliable, smooth, for light duty
HEGLERFLEX-EGL 16 - 63
orange
PE
HEGLERPLAST-EL 16 - 25 HEGLERPLASTEPKM
16 - 63
DIN EN 50086-2-2/ VDE 0605 Teil 2-2
corrugated ins. DIN EN 50086-2-2/ smooth outs. VDE 0605 Teil 2-2 corrugated
DIN EN 50086-2-2/ VDE 0605 Teil 2-2
smooth
DIN EN 50086-2-2/ VDE 0605 Teil 2-2
RAL 7035 PVC-U grey
smooth
DIN EN 50086-2-1/ VDE 0605 Teil 2-1
16 - 63
RAL 7035 PVC-U grey
smooth
DIN EN 50086-2-1/ VDE 0605 Teil 2-1
HEGLERPLASTEPKS
16 - 63
RAL 7035 PVC-U grey
smooth
DIN EN 50086-2-1/ VDE 0605 Teil 2-1
electrical conduit, smooth, rigid, for HEGLERPLASTmedium duty, flame-retardant, UV-stabilized, EPKMU impact resistant
16 - 63
white
smooth
DIN EN 50086-2-1/ VDE 0605 Teil 2-1
electrical conduit, smooth, rigid, for medium duty, flame-retardant, halogen-free
HEGLERPLASTEPKMH
16 - 63
RAL 7035 PPO grey
smooth
DIN EN 50086-2-1/ VDE 0605 Teil 2-1
STAPAFLEX-EP
16 - 63
sheet iron, lea- grooved ded, with paper layers
armoured steel conduit, pliable, for heavy duty, corrosion resistant by PVC-P coating
STAPAFLEX-EPY
16 - 63
sheet iron, lea- corrugated ins. DIN EN 50086-2-2/ ded, with paper smooth outs. VDE 0605 Teil 2-2 layers and PVC-P coating
armoured steel conduit, rigid, smooth, for heavy duty
STAPA-ESs
16 - 63
black
steel
smooth
DIN EN 50086-2-1/ VDE 0605 Teil 2-1
STAPA-EGs
16 - 63
black
steel
smooth
DIN EN 50086-2-1/ VDE 0605 Teil 2-1
STAPA-ESv
16 - 63
galvanized steel
smooth
DIN EN 50086-2-1/ VDE 0605 Teil 2-1
STAPA-EGv
16 - 63
galvanized steel
smooth
DIN EN 50086-2-1/ VDE 0605 Teil 2-1
ALU-ES
16 - 63
aluminium
smooth
DIN EN 50086-2-1/ VDE 0605 Teil 2-1
ALU-EG
16 - 63
aluminium
smooth
DIN EN 50086-2-1/ VDE 0605 Teil 2-1
HEKAPLAST-S
63 - 200 black special colours
PE-HD
HEKAPLAST-R
40 - 200 black PE sp. colours
twin wall pipe, corrugated outside, smooth inside, for heavy duty, flame-retardant
HEKAPLAN
110/100 black 165/150
PVC-U
plastic pipe, flexible, corrugated, for light duty, flame-retardant
HEKAWELL
50 - 200 yellow
PVC-U
armoured steel conduit, pliable, STAPAFLEX pliable armoured for heavy duty steel conduits
HEGLER-ALU aluminium conduit, smooth, rigid, smooth rigid alu- for heavy duty minium conduits aluminium conduit, smooth, rigid, for heavy duty
28
Raw material
orange
electrical conduit, smooth, rigid, for heavy duty, flame-retardant
Cable ducts
DN (mm) Colour
HEGLERFLEX-EYL 16 - 63
HEGLERPLAST electrical conduit, smooth, rigid, for light duty, flame-retardant smooth rigid electrical conduelectrical conduit, smooth, rigid, for its medium duty, flame-retardant
STAPA smooth rigid armoured steel conduits
Product name
twin wall pipe, corrugated outside, smooth inside, for heavy duty
PVC-U
DIN EN 50086-2-2/ VDE 0605 Teil 2-2
DIN EN 50086-2-4/ VDE 0605 Teil 2-4 DIN EN 50086-2-4/ VDE 0605 Teil 2-4
corrugated
DIN 1187
O
33333
43212
O
O
23232
O
33232
O
22412
O
O
-15 to 90 °C
4
-5 to 60 °C
5
-5 to 60 °C
5
-15 to 105 °C
5
-5 to 60 °C
6
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
-5 to 105 °C
6
O
O
O
O
O
-5 to 105 °C
6
O
O
-25 to 60 °C
7
-5 to 60 °C
8
O
22211
O
O
33211
O
O
O
O
O
43211
O
O
O
O
33411
O
O
O
33421
O
O
44562
44412
O
4
O
O
O
-25 to 105 °C
O
O
O
see page
O
O
Temperature range for use
33212
Subsoil installation
O
O
Vehicle and wagon installation
22212
Installation in melted asphalt
O
Installation in bituminous material
O
Installation in tamped concrete
O
Installation in vibrated concrete
22322
Installation in heaped concrete
O
Concealed installation
O
Surface installation
O
Classification 22432
Machine and apparatus installation
Seite 29
Installation in wooden and prefabricated parts and in false floors
12:35 Uhr
Installation in prefabricated concrete parts
19.06.2006
Installation in floor finish
E-Rohr-Katalog_engl_neu.qxd
O
O
O
O
O
O
O
-5 to 60 °C
8
O
O
O
O
O
-5 to 60 °C
9
O
O
O
O
O
O
-25 to 60 °C
9
O
O
O
O
O
O
O
O
-25 to 90 °C
9
O
O
O
O
O
O
O
O
O
O
-45 to 250 °C
10
O
O
O
O
O
O
O
O
O
O
-25 to 60 °C
10
44561
O
O
O
O
O
O
O
O
O
O
-45 to 250 °C
12
55561
O
O
O
O
O
O
O
O
O
O
-45 to 250 °C
12
44571
O
O
O
O
O
O
O
O
O
O
-45 to 400 °C
13
55571
O
O
O
O
O
O
O
O
O
O
-45 to 400 °C
13
O
O
O
O
O
O
O
O
O
O
O
14
O
O
O
O
O
O
O
O
O
O
O
14
O
O
O
-40 to 105 °C
20
O
O
O
-40 to 105 °C
20
O
O
O
-5 to 60 °C
21
O
O
O
-5 to 60 °C
21
29
E-Rohr-Katalog_engl_neu.qxd
30
19.06.2006
12:35 Uhr
Seite 30
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:35 Uhr
Seite 31
31
E-Rohr-Katalog_engl_neu.qxd
19.06.2006
12:36 Uhr
Seite 32
HEGLER PLASTIK GMBH · D-97714 Oerlenbach/Unterfranken Phone ++49 (0) 97 25 66-0 · Fax ++49 (0) 97 25 66-115
Edition II/1