Electromechanical and solid-state relays Zelio Relay Catalogue September 2009
Reduce the size of your enclosures and, at the same time, increase machine reliability The new Zelio Relay items Electromechanical relays RSL Only 6 mm wide, thus saving considerable space in your enclosures
6 mm wide
Solid-state relays SSR Unlimited service life provided by electronic technology Unlimited service life
Contents Presentation
Choose compactness with Zelio Relay RSL ....................................................................... 2-3 Choose long life and silent operation with Zelio Relay SSR ................................................. 4-5 Electromechanical and solid-state relays panorama ........................................................... 6-7
Technical characteristics Zelio Zelio Zelio Zelio
Relay RSL ................................................................................................................................. 8-15 Relay RSB, RXM, RUM, RPM ............................................................................................ 16-49 Relay ABR, ABS .................................................................................................................... 50-69 Relay SSR .............................................................................................................................. 70-77
Make the most of your energy 1
Choose compactness with Zelio Relay RSL Only 6 mm wide, thus reducing the size of your enclosures
> A solution for any application
A complete offer > An offer with maximum flexibility, comprising: • complete products: a single reference for a relay mounted on a socket, • products for customer assembly: select the relay and associated socket according to your application. > Wide choice of sockets available covering a range of voltages from 12 to 230 V.
An offer that meets the most demanding standards • Conformity with the European RoHS (Restriction of Hazardous Substances) directive. • Conformity to international standards IEC/EN 61810-1, UL508, CSA C22.2 N°14, GOST.
100% RoHS Schneider Electric commits itself to reducing the environmental impact of its products 2
> Reliability in any situation Protection integrated in the socket The assurance of reliable protection of the relay irrespective of the supply voltage used.
LED indicator Power on and relay status LED indicator.
«Standard» and «low level» version relays For high breaking capacity or low level current application requirements.
6A
Up to breaking capacity
> Simplicity of installation and cabling
Simple maintaining of relay in socket and its release/removal
Using locking/unlocking lever.
Simplification of cabling
Commoning link available as accessory.
Simple mounting on DIN rail Choice of 2 connection techniques Suitable for the majority of your applications.
Screw connector
Spring terminal 3
Choose long life and silent operation with Zelio Relay SSR > Heat exchange guaranteed The new solid-state relays SSR with SCR (Semiconductor Controlled Rectifier) outputs offer you two alternatives:
SSRD range
Directly mounted with heat sink to provide heat exchange, they are easily mounted by clipping directly onto DIN rail and can also be mounted.
SSRP range
mounted, either on their own or combined with a heat sink for applications requiring considerable heat exchange.
SS
RA H1
AS SE 0812 MB LE D IN
ME XIC O
SSRP relay mounted on heat sink with thermal interface
4 4
> Distinctive indication A green LED on the front face of the products provides instant indication of the relay input status.
> High performance High breaking capacities
• From 10 to 125 A for relays SSRP • From 10 to 45 A for relays SSRD
Wide supply voltage range
Unlimited service life due to electronic relay technology
• From 3 to 32 VDC and 90 to 280 VAC
Outputs suited to applications
• From 24 to 280 VAC and 48 to 530/660 VAC
• Only 22.5 mm and up to 45.5 mm wide
Complete silence when switching
Unlimited service life
providing suitability for building and hospital applications
Extreme compactness
• No preventive maintenance, relays SSR have a unlimited service life
Silence of electronic technology • Complete silence when switching
Insensitive to vibration
• Even in the event of excessive vibration, the relay will not change state
High switching frequency particularly on packaging and textile machines
> Conformity to
international standards
100% RoHS
Schneider Electric commits itself to reducing the environmental impact of its products
5
Panorama Zelio Relay Electromechanical relays
Number CO s Current
1 CO
1 or 2 CO
1 or 2 CO
2, 3 or 4 CO
6A
8-12-16 A
5-12 A
6-10-12 A
Plugs into socket
Mounting References Pages
On DIN rail
RSL
RSB
ABR
RXM
8 to 15
16 to 21
50 to 69
22 to 29
Electromechanical relay advantages • Wide choice of number of s (up to 4) • Easy installation and maintenance: Plug-in relay for socket mounting (universal format) status mechanical indicator and “Relay On” LED indicator Lockable “Test” button for testing relay operation • Electrically separated inputs and outputs, allowing different voltages
Solid-state relays
2, 3 or 4 CO
1, 2, 3 or 4 CO
1 NO
1 NO
1 NO
10 A
15A
3A
10 ...45 A
10 ...125 A
On DIN rail
On DIN rail
On
Plugs into socket RUM
RPM
ABS
SSRD
SSRP
30 to 39
40 to 49
50 to 69
70 to 77
70 to 77
Solid-state relay (SSR) advantages • Unlimited service life • Wide supply voltage range and high breaking current (up to 125 A), suited to packaging and textile machines • “Relay On” LED indicator • Completely silent switching, providing suitability for building and hospital applications • Insensitive to vibration
Zelio Relay - plug-in relays
Selection guide
RSL slim interface relays
Plug-in relays PF090211
Application
1 2
Number and type of s / conventional thermal current (Ith on N/O ) Control voltage range type
4
c
12…60 V
Standard
Yes
Low level
Yes
Type of pins
Flat (PCB type, reinforced)
Operating voltage
Up to a 400 V / c 300 V
Durability (operating cycles)
Electrical, resistive load
60 000
Mechanical, no-load
10 000 000
Relay type
RSL 1pB4pD
Pages
14 PF090209
3
1 C/O / 6 A
5
7 8
Conventional thermal current (Ith)
6A
Connection
Screw connector
LED
Yes
Protection circuit
Yes
Accessories
Socket identification legend
Yes
Bus jumper
Yes
Partition plate
Yes
Socket type
RSL ZVpp
Pages
14 PF090206
6
9 10
Slim interface relays, pre-assembled
RSL 1PVpp
Pages
14
1 2 3
PF090210
4 5 6
6A Spring terminals Yes Yes
7
Yes Yes Yes
RSL ZRpp
8
PF090207
14
9 10
RSL 1PRpp 14
Zelio Relay - plug-in relays
Presentation
RSL slim interface relays
Presentation
RSL slim interface relays offer the advantages of compact size and modular design: their slim width (6 mm) saves space when mounting on a 5 rail at the back of an enclosure.
1
RSL relays are available in two versions: b pre-assembled range: a single reference comprising a relay mounted on its socket. v The socket includes a protection circuit (against reverse polarity and surge) and an LED indicator as standard. v Two types of connector are available for wire connection: screw connectors or spring terminals. v This pre-assembled solution covers a wide range of operating voltages from 12 to 230 V. b range for customer assembly: v The relay (standard or low level) and the socket are selected, as required, according to the operating voltage of the application. v For maintenance: an RSL slim relay can be replaced without any need to disconnect the socket wiring.
2 3 1
4
2
4
3
Description
RSL slim interface relays, pre-assembled 1 2 3 4
6 A relay (standard or low level) with 1 C/O . Lever for retaining, or easy withdrawal of the relay from its socket. Sockets: wire connection by screw connector or by spring terminals. All sockets have a built-in protection circuit and LED indicator.
6
PF090213
5
PF090208
RSL slim interface relay
7
1 Five flat, reinforced pins (PCB type). 1 1
8
4
2 3
Sockets for RSL slim interface relays 1 2 3 4 5
Five female s for the relay pins. Retaining lever with marker label. Wire connection by screw connector or by spring terminals. Protection circuit and LED indicator (built into the socket) Locating slot for mounting on 5 rail.
10
PF090212
9
5 Presentation : page 10
10
Characteristics : page 11
References : page 14
Dimensions, schemes : page 15
Characteristics
Zelio Relay - plug-in relays RSL slim interface relays
General characteristics
Conforming to standards
IEC 61810-1, UL 508, CSA C22-2 No. 14
Product certifications
UL, CSA, GOST
Ambient air temperature around the device
Vibration resistance conforming to IEC/EN 60068-2-6
Storage
°C
- 40… + 85
Operation
°C
- 40… + 55
In operation
10 gn
Not operating
5 gn
Degree of protection
Conforming to IEC/EN 60529
IP 40 (Relays) IP 20 (Sockets)
Shock resistance conforming to IEC/EN 60068-2-27
Opening
10 gn
Closing
5 gn
Protection category
RT III
Mounting position
Any
Insulation characteristics
Rated insulation voltage (Ui)
V
250 (IEC)
Rated impulse withstand voltage (Uimp)
kV
6
Dielectric strength (rms voltage)
Between coil and
aV
4000
Between s
aV
1000
1 2 3 4 5 6 7 8 9 10
11
Zelio Relay - plug-in relays
Characteristics (continued)
RSL slim interface relays
characteristics
1 2 3
Relay type
RSL1ABppp
RSL1GBppp
Number and type of s
1 C/O
1 C/O low level
materials
AgSnO2
AgSnO2 - gold plated
A
6
6
N/C
A
6
6
N/O
A
6
6
Conventional thermal current (Ith)
For ambient temperature y 55 °C
Rated operational current in utilisation categories AC-1 and DC-1
Conforming to IEC Conforming to UL
A
6
6
Switching current
Minimum
mA
100
1 (at 50 mW)
Switching voltage
Rated
aV
250
250
Maximum
V
a 400, c 300
a 250, c 300
Minimum
V
12
1 (at 50 mW)
A
6 / a 250 V, 0.5 mm
VA
1500
W
18…150 (depending on the voltage)
mW
120
Nominal load (resistive) Switching capacity
4 5
Maximum
a c
Minimum
50
Maximum operating rate In operating cycles
No-load
72 000
Under load
360
Mechanical durability
In millions of operating cycles
10
Electrical durability Resistive load In millions of operating cycles Inductive load
See curves below 0.05 (N/O /250 V, 3 A, AC-15) Maximum switching capacity on c load
6
200 100
Resistive load a 250V
AgSnO2
Resistive load 105
20
7
10 0,1 0,2
Coil characteristics
9
107
106
50 40 30
8
Electrical durability Cycles
Voltage c
300
Average consumption
c
Drop-out voltage threshold
c
Operating time (response time)
W
5
10 20 Current c
104
0
1
2
4 5 6 3 Switching current (A)
0.17 u 0.05 Uc
ms
12 max
Between coil de-energisation and making of the Off-delay
c
ms
5 max
V
12
24
48
60
JD
BD
ED
ND
Ω
848
3390
10 600
20 500
Min.
V
8.4
16.8
33.6
42
Max.
V
16.8
33.6
67.2
84
Average resistance at 23 °C ± 10% Operating voltage limits
10
12
2
c
Relay control voltage codes
Presentation : page 10
1
Between coil energisation and making of the On-delay
Control circuit voltage Uc DC supply
0,5
Characteristics : page 11
References : page 14
Dimensions, schemes : page 15
7
8
Characteristics (continued)
Zelio Relay - plug-in relays RSL slim interface relays
Socket characteristics Socket type
RSL ZVpp
RSL ZRpp
Relay types used
RSL 1pppp
RSL 1pppp
Conforming to standards
IEC 61984, UL 508, CSA C22-2 No. 14
Product certifications
UL, CSA, GOST
terminal arrangement
Separate
Separate
Wire connection method
Screw connector
Spring terminals
mm
6.2
6.2
Conventional thermal current (Ith)
A
6
Maximum operating voltage
V
300
Between adjacent output s
Vrms
2500
Between input and output s
Vrms
2500
Between s and 5 rail
Vrms
2500
- 40…+ 70 / - 40…+ 55 for U > 80 V
Width
1 2
Electrical characteristics
Insulation characteristics
3
General characteristics Ambient air temperature around the device
Operation
°C
Storage
°C
Degree of protection
Conforming to IEC/EN 60529
Cabling
Solid cable 1 conductor without cable end
mm²
0.2…2.5
0.2…1.5
AWG
24…14
24…16
Flexible cable with cable end
mm²
0.2…2.5
0.2…1.5
AWG
24… 14
24…16
Screw size
mm
M 2.5
Maximum tightening torque
Nm
0.5
1 conductor
- 40…+ 85
4
IP 20
5
10 N…40 N (0.2 …1.5 mm²)
Mounting
On 35 mm 5 rail
Fixing on 5 rail
By plastic compression spring
Terminal referencing
IEC
LED indicator
Yes (built-in)
Protection circuit
Yes (built-in)
Wire connection method
Screw connector
6 Spring terminal
7 Sockets operating voltage
Operating voltage
Tolerance
V Socket type
RSLZVA1, RSLZRA1
Control circuit voltage (relay) V
c/a 12
+ 20% / - 5%
c 12
c/a 24
+ 20% / - 10%
c 24
c/a 48
+ 20% / - 10%
c 48
c/a 60
+ 20% / - 10%
c 60
RSLZVA3, RSLZRA3
c/a 110
+ 15% / - 20%
c 60
RSLZVA4, RSLZRA4
c/a 230
+ 15% / - 20%
c 60
RSLZVA2, RSLZRA2
8 9 10
13
Zelio Relay - plug-in relays
References
RSL slim interface relays
Slim interface relays, pre-assembled PF090207
Relays mounted on socket equipped with LED and protection circuit PF090206
1
Sold in lots of 10
1 C/O - Thermal current (Ith) 6A Operating voltage
Control circuit voltage
Socket type Screw connector Unit reference
V
2 RSL 1PVpp
3
RSL 1PRpp
Spring terminal Weight
V
Unit reference
kg
Weight kg
c/a 12
c 12
RSL 1PVJU
0.031
RSL 1PRJU
0.029
c/a 24
c 24
RSL 1PVBU
0.031
RSL 1PRBU
0.029
c/a 48
c 48
RSL 1PVEU
0.031
RSL 1PREU
0.029
c/a 110
c 60
RSL 1PVFU
0.031
RSL 1PRFU
0.029
c/a 230
c 60
RSL 1PVPU
0.031
RSL 1PRPU
0.029
Slim interface relays for customer assembly: relay + socket Relays with flat, reinforced pins (PCB type) PF090211
4
Sold in lots of 10
1 C/O - Thermal current (Ith) 6A Standard Control circuit voltage
Unit reference
V RSL 1pppp
5
Low level Weight
Unit reference
kg
Weight kg
c 12
RSL 1AB4JD
0.006
RSL 1GB4JD
0.006
c 24
RSL 1AB4BD
0.006
RSL 1GB4BD
0.006
c 48
RSL 1AB4ED
0.006
RSL 1GB4ED
0.006
c 60
RSL 1AB4ND
0.006
RSL 1GB4ND
0.006
PF090209
6
PF090210
Sockets equipped with LED and protection circuit Sold in lots of 10
Socket type Screw connector Operating voltage
For use with relays
Unit reference
V
7 RSL ZVAp
8
Spring terminal Weight
Unit reference
kg
Weight kg
c/a 12 and c/a 24
RSL 1pB4JD RSL 1pB4BD
RSL ZVA1
0.025
RSL ZRA1
0.023
c/a 48 and c/a 60
RSL 1pB4ED RSL 1pB4ND
RSL ZVA2
0.025
RSL ZRA2
0.023
c/a 110
RSL 1pB4ND
RSL ZVA3
0.025
RSL ZRA3
0.023
c/a 230
RSL 1pB4ND
RSL ZVA4
0.025
RSL ZRA4
0.023
RSL ZRAp
Accessories for sockets Sold in lots of 10 RSL Z2
9 10
Description
Compatibility
Unit reference
Clip-in legends (sheet of 64 legends)
With all sockets
RSL Z5
0.001
Bus jumper (20-pole jumper)
With all sockets
RSL Z2
0.003
Partition plate
With all sockets
RSL Z3
0.001
Characteristics : page 11
References : page 14
RSL Z3
Presentation : page 10
14
Dimensions, schemes : page 15
Weight kg
Zelio Relay - plug-in relays
Dimensions, schemes
RSL slim interface relays
Slim interface relays, pre-assembled
RSL 1PRpp (spring terminals)
1
51,5
6,2
2
101
95
35,3
30,1
RSL 1PVpp (screw connector)
6,2
51,5
78,6
6,2
3
6,2
78,6
Relays for customer assembly
RSL 1pppp with flat, reinforced pins (PCB type)
3,5±0,5
11,34 (1) (1) 1,9
5 max
1 C/O
4
14
28 max
11 12 A1
3,78
15 max
5
A2
(1): 5.04 mm
Sockets equipped with LED and protection circuit
RSL ZRpp (spring terminals) 35,3
30,1
RSL ZVpp (screw connector)
101
95
6 7
51,5
6,2
6,2
51,5
78,6
6,2
6,2
78,6
Socket connections
8
Example of RSL Z2 bus jumper mounting on sockets
RSL ZVpp (screw connector)
RSL ZRpp (spring terminals)
12
12
11
11
14
Side view
(1)
14
9
(3)
(2) A1 A2
Protection circuit
14
A1
11
A2
12
Protection circuit
14
(4)
11 12
A1
A1
A2
A2
10 (1) A1 (2) A2 (3) Bus jumper polarity A1 (4) Bus jumper polarity A2
15
Zelio Relay - plug-in relays
Selection guide
Application
Plug-in relays Interface relays
1
Miniature relays
2 3
Number and type of s / conventional thermal current (Ith on N/O )
1 C/O / 16 A 1 C/O / 12 A 2 C/O / 8 A
2 C/O / 12 A 3 C/O / 10 A 4 C/O / 6 A 4 C/O / 3 A (low level)
24…240 V 6…110 V
24…240 V 12…220 V
Type of pins
Flat (Faston type)
Flat (Faston type)
Operational voltage
Up to a 400 V / c 300 V
Up to 250 V
Control circuit voltage
4 5 6
a c
Durability (operating cycles)
Electrical, resistive load Mechanical, no-load
100 000 30 000 000
100 000 10 000 000
Functions
LED Mechanical indicator Lockable test button Low level s
Yes (with protection modules) – – –
Yes (depending on version) Yes Yes Yes (depending on version)
Type reference
RSB
RXM
Pages
20
25 and 26
Conventional thermal current (Ith)
12 A (1)
10 A
12 A (2)
terminal arrangements
Separate
Mixed
Separate
Connection
Connector
Screw clamp terminals or connector
Connector
Accessories Protection modules Timer module Maintaining clamps Socket identification legend
Yes – Yes Yes – – –
Yes – Yes Yes (except RXZ E2M114) Yes Yes – Yes
RSZ E1SppM
RXZ E2Mppp
7 8 9
Mounting adapters for 5 rail Mounting adapters with fixing lugs Bus jumper, 2-pole (Ith = 5 A)
10
Associated socket types
Pages
16
RXZ E2Sppp
20 26 26 (1) When using relay RSB 1A160pp with socket RSZ E1S48M, terminals must be linked. (2) Except for sockets RXZ E2S11pM: 10 A.
Universal relays
Power relays
1 2
2 C/O / 10 A 3 C/O / 10 A 3 C/O / 3 A (low level)
2 C/O / 10 A 3 C/O / 10 A
1 C/O / 15 A 2 C/O / 15 A 3 C/O / 15 A 4 C/O / 15 A
24…230 V 12…220 V
12…110 V
24…230 V 12…110 V
Cylindrical
Flat (Faston type)
Flat (Faston type)
Up to 250 V
Up to 250 V
100 000 5 000 000
100 000 (3) 10 000 000
Yes (depending on version) Yes Yes Yes (depending on version)
Yes (depending on version) Yes Yes –
–
RUM
RPM
33
43
3 4 5 6 7
12 A Mixed
16 A Separate
Connector
Screw clamp terminals
Yes Yes Yes Yes – – –
Yes
Yes Yes (for 3 and 4-pole) Yes (on socket RPZ F1) Yes Yes Yes –
RUZ M
RUZ SM
34 (3) 100 000 for RPM1 and RPM2; 60 000 for RPM3 and RPM4.
8
Mixed
RUZ SF3M
RPZ Fp
34
44
9 10
17
Zelio Relay - plug-in relays
Presentation, characteristics
5
523139
1
Presentation of the range The RSB interface relay range comprises: 1 12 A relays with 1 C/O , 16 A relays with 1 C/O and 8 A relays with 2 C/O s. 2 Sockets with separate terminals. 3 Protection modules (diode, diode + LED, RC circuit or varistor + LED). All these modules are common to all sockets. 4 A plastic maintaining clamp for all sockets. 5 Clip-in legends for the sockets.
2
4
2
1
Socket description Sockets with separate terminals (1) 1 Connection by connector. 2 Five or eight female s for the relay pins. 3 A fixing hole for mounting. 4 Location for protection modules. 5 Locking components for plastic maintaining clamp. 6 Locating slot for mounting on 5 rail.
3
1
535188
3
RSB interface relays
Inputs
Outputs
4
2 5 3
(1) The inputs and outputs are separated from the relay supply.
4
5
6
Relay supply
General characteristics
6 7 8 9
Conforming to standards Product certifications Ambient air temperature around the device
Storage Operation Vibration resistance Conforming to IEC/EN 60068-2-6 Degree of protection Conforming to IEC/EN 60529 Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position
Insulation characteristics Rated insulation voltage (Ui) Conforming to IEC/EN 60947 Rated impulse withstand voltage (Uimp) Dielectric strength Between coil and (rms voltage) Between poles Between s
V kV aV aV aV
400 3.6 (1.2/50 µs) 5000 2500 1000 RSB 1A160pp 1 C/O
RSB 2A080pp 2 C/O
A
RSB 1A120pp 1 C/O AgNi 12
16
8
A A
12 6
16 8
8 4
mA V V A A VA W mW
5 a 400, c 300 5 12 / 250 a V 12 / 28 c V 3000 336 300 72 000 600
16 / 250 a V 16 / 28 c V 4000 448
8 / 250 a V 8 / 28 c V 2000 224
characteristics Relay type Number and type of s materials Conventional thermal current (Ith) Rated operational current in utilisation categories AC-1 and DC-1 Switching current Switching voltage
For ambient temperature y 40°C Conforming to IEC
“C” “O”
Minimum Maximum Minimum
Nominal load (resistive)
10
°C °C
IEC/EN 61810-1, UL 508, CSA C22-2 n° 14 UL, CSA - 40…+ 85 c - 40…+ 85, a - 40...+ 70 > 10 gn (10..150 Hz) IP 40 5 gn 10 gn RT I Any
Switching capacity
Maximum
Maximum operating rate In operating cycles/hour
Minimum No-load Under load
Presentation: page 18
References: page 20
18
a c
Characteristics: page 19
Dimensions, schemes: page 21
Zelio Relay - plug-in relays
Characteristics
RSB interface relays
Relay type Mechanical durability Electrical durability In millions of op. cycles
107
A 106
C B
105
RSB 1A120pp RSB 1A160pp RSB 2A080pp u 30 12 A - 250 V: u 0.1 16 A - 250 V: u 0.07 8 A - 250 V: u 0.1 See curves below Reduction coefficient for inductive load a Maximum switching capacity on resistive load (depending on power factor cos j) c Reduction coefficient (A)
Durability (Number of operating cycles)
In millions of operating cycles Resistive load Inductive load Electrical durability of s Resistive load a
1 0,
Current c
characteristics (continued)
0,6 0,5
1
50
B
16 12 5
2
C
A
2 1
0,4
0,5
104
0,3 0
0,4
0,8 1 1,2
1,6
2
3
0,1
1
0,6
0,4
10
0,2
20 30
50
100
200 300
Voltage c
Switching capacity (kVA)
A RSB 2A080pp B RSB 1A160pp C RSB 1A120pp. Durability (inductive load) = durability (resistive load) x reduction coefficient. Coil characteristics
Average consumption Drop-out voltage threshold Operating time Between coil energisation and (response time) making of the On-delay
a c Between coil de-energisation and a making of the Off-delay c Control circuit voltage Uc Relay control voltage codes d.c. supply Average resistance at 20 °C ± 10% Operating Min. voltage limits Max. Relay control voltage codes a.c. supply Average resistance at 20 °C ± 15% 60 Hz Operating Min. 50 Hz voltage limits 60 Hz Max. 50/60 Hz
Socket characteristics
ms ms ms ms V W V V W V V
Socket type Relay types used terminal arrangement Wire connection method Product certifications Conforming to standards
Electrical characteristics
c 0.45 W, a 0.75 VA ≥ c 0.1 Uc, ≥ a 0.15 Uc 12 9 10 4 6 12 24 RD JD BD 90 360 1440 4.8 9.6 19.2 6.6 13.2 26.4 – – B7 – – 400 – – 19.2 – – 20.4 – – 26.4
4 48 ED 5700 38.4 52.8 E7 1550 38.4 40.8 57.6
60 ND 7500 48 66 – – – – –
RSZ E1S35M RSB 1A120pp Separate Connector e IEC 61984, UL, CSA
Conventional thermal current (Ith) Maximum operating voltage
A V
12 300
Between adjacent output s Between input and output s Between s and 5 rail
Vrms Vrms Vrms
2500 2500 2500
Ambient air temperature around the device Degree of protection Cabling screw connector
°C °C
- 25…+ 85 - 40…+ 85 IP 20 0.5…2.5 mm2 - AWG 20…AWG 14 0.5…1.5 mm2 - AWG 20…AWG 16 0.25…2.5 mm2 - AWG 22…AWG 14 0.25…1 mm2 - AWG 22…AWG 17 0.8 / M3 screw On 35 mm 5 rail / on By plastic compression spring IEC No Yes, plastic No All RZM ppp Yes
Insulation characteristics
General characteristics
Operation Storage Conforming to IEC/EN 60529 Solid cable 1 conductor without cable end 2 conductors Flexible cable 1 conductor with cable end 2 conductors Maximum tightening torque / Screw size Mounting Fixing on 5 rail Terminal referencing Bus jumper (Ith: 5 A) Compatibility with the metal maintaining clamp Timer module Protection module Clip-in legends Wire connection method Screw connector
Nm
110 FD 25 200 88 121 – – – – –
120 – – – – F7 10 200 96 102 144
220 – – – – M7 35 500 176 187 264
230 – – – – P7 38 500 184 195.5 276
240 – – – – U7 42 500 192 204 288
RSZ E1S48M RSB 2A080pp, RSB 1A160pp (1)
5 6 7 8 9 10
(1) When using the relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 21.
19
Zelio Relay - plug-in relays
References
560583
Relays for standard applications Control circuit voltage
1 2 RSB 1A120JD + RZM 031FPD + RSZ E1S35M
560584
3 4 5
Sold in lots of
Number and type of s - Thermal current (Ith) 1 C/O - 12 A 1 C/O - 16 A 2 C/O - 8 A Unit Unit Unit reference (1) reference (1) reference (1)
Weight
V c6
10
RSB 1A120RD
RSB 1A160RD
RSB 2A080RD
kg 0.014
c 12
10
RSB 1A120JD
RSB 1A160JD
RSB 2A080JD
0.014
c 24
10
RSB 1A120BD
RSB 1A160BD
RSB 2A080BD
0.014
c 48
10
RSB 1A120ED
RSB 1A160ED
RSB 2A080ED
0.014
c 60
10
RSB 1A120ND
RSB 1A160ND
RSB 2A080ND
0.014
c 110
10
RSB 1A120FD
RSB 1A160FD
RSB 2A080FD
0.014
a 24
10
RSB 1A120B7
RSB 1A160B7
RSB 2A080B7
0.014
a 48
10
RSB 1A120E7
RSB 1A160E7
RSB 2A080E7
0.014
a 120
10
RSB 1A120F7
RSB 1A160F7
RSB 2A080F7
0.014
a 220
10
RSB 1A120M7
RSB 1A160M7
RSB 2A080M7
0.014
a 230
10
RSB 1A120P7
RSB 1A160P7
RSB 2A080P7
0.014
a 240
10
RSB 1A120U7
RSB 1A160U7
RSB 2A080U7
0.014
Connection
Relay type
Connector
RSB 1A120pp RSB 1A160pp (2) RSB 2A080pp
Sold in lots of 10 10
Unit reference RSZ E1S35M RSZ E1S48M
Weight kg 0.060 0.050
For use with
Voltage
Sold in lots of
Unit reference
Weight
V c 6…230
10
RZM 040W
kg 0.003
Sockets 12 A, a 300 V RSB 1A160BD + RSZ E1S48M
Description
7 8
terminal arrangement Separate
Protection modules
560582
6
RSB interface relays
Diode
All sockets
RC circuit
All sockets
a 24…60 a 110…240
10 10
RZM 041BN7 RZM 041FU7
0.010 0.010
Diode + green LED
All sockets
c 6…24 c 24…60 c 110…230
10 10 10
RZM 031RB RZM 031BN RZM 031FPD
0.004 0.004 0.004
Varistor + green LED
All sockets
c or a 6…24 c or a 24…60 c or a 110…230
10 10 10
RZM 021RB RZM 021BN RZM 021FP
0.005 0.005 0.005
Sold in lots of 10 10
Unit reference RSZ R215 RSZ L300
RSB 2A080BD + RSZ E1S48M
Accessories 560585
Description Plastic maintaining clamp Legend
9
For use with All sockets All sockets
Weight kg 0.002 0.001
(1) To order a relay complete with socket (sold in lots of 20): add suffix S to one of the following voltage codes JD, BD, B7, P7 or F7. Example: RSB 2A080BD + RSZ E1S48M becomes RSB 2A080RBS. (2) When using the relay with socket RSZ E1S48M, terminals must be linked. See connection schemes on page 21. RSZ R215
10 Presentation: page 18
20
References: page 20
Characteristics: page 19
Dimensions, schemes: page 21
Zelio Relay - plug-in relays
Dimensions, schemes
RSB interface relays
Dimensions
Interface relays RSB 1A120pp
1
RSB 2A080pp, RSB 1A160pp
12,5 7,5
12,5 7,5
29
2
2,5
15
16,5
5
29
5
15,7 3,9
2,5
3,5
3,5
15,7 3,9
Sockets RSZ E1S35M
RSZ E1S48M
67 61
3
67 61
(4)
(4)
11
21
11
14
24
14
12
22
12
(1) 78,5
78,5
(1)
(3)
29,4
(2) A2
(2) A2
A1
15,5
27,5 34,5
5
29,4
(3)
4
A1
15,5
27,5 34,5
6
50
50 (1) Relays (2) Protection module (3) Maintaining clamp (4) Legend
Schemes
Interface relays
14
21
11
22
12
A2
A1
A2
A1
12
24
A2 A1
22
24
14
21
11
22
12
A1
11
21
11
14
12
A2
24
8 9
A2
14
7
RSB 2A080pp
A1
14/24
12/22
A2 A1
RSB 1A160pp
11/21
14
12
11
RSB 1A120pp
When using relay RSB 1A160pp with socket RSZ E1S48M terminals 11 and 21, 14 and 24, 12 and 22 must be linked
Protection modules RZM 040W
RZM 041ppp
RZM 031ppp
10
RZM 021ppp
– A2
– A2
– A2
– A2
+ A1
+ A1
+ A1
+ A1
21
Zelio Relay - plug-in relays
Presentation
Presentation of the range
7
524766
1
RXM miniature relays
The RXM miniature relay range comprises: 1 12 A relays with 2 C/O s, 10 A relays with 3 C/O s, 6 A relays with 4 C/O s and 3 A “low level” relays with 4 C/O s. All these relays have the same dimensions. 2 Sockets with mixed or separate terminals. 3 Protection modules (diode, RC circuit or varistor). All these modules are common to all sockets. 4 A metal maintaining clamp for all sockets. 5 A plastic maintaining clamp for all sockets. 6 A 2-pole bus jumper that can be used on sockets with separate terminals in order to simplify cabling when creating an equipotential link between the coil terminals. 7 Clip-in legends for all the sockets except RXZ E2M114.
2
1
2
4 or 5 6
3
3
106557
8 1 2 3
4
4
106661
106660
9
10
Socket description
6 1
106014
6
9
106662
5
7 6
5
Relay description
1 Spring return pushbutton for testing the s (green: c, red: a). 2 Mechanical “relay status” indicator. 3 Removable lock-down door enabling forced maintaining of the s for test sequences or maintenance purposes. During operation, this lock-down door must always be in the closed position. 4 LED (depending on version) indicating the relay status. 5 Removable legend for relay identification. 6 Four notches for rail mounting adapter or mounting adapter with fixing lugs. 7 Eight, eleven or fourteen Faston type pins. 8 Area by which the product can be easily gripped. 9 Mounting adapter enabling direct mounting of the relay on a . 10 Mounting adapter enabling direct mounting of the relay on a 5 rail.
Outputs
2
7
Sockets with mixed terminals (1) 1 Connection by screw clamp terminals or screw connector. 2 Fourteen female s for the relay pins. 3 Location for protection modules. 4 Locking components for plastic and metal maintaining clamps. 5 Locating slot for mounting on 5 rail with its compression spring or fixing clip. 6 Two or four fixing holes for mounting.
4 3 Inputs
8
5
5
Relay supply
6 106015
1 Inputs
9
Outputs
2 4
Sockets with separate terminals (2) 1 Connection by screw connector. 2 Eight, eleven or fourteen female s for the relay pins. 3 Location for protection modules. 4 Locking components for plastic and metal maintaining clamps. 5 Locating slot for mounting on 5 rail with its compression spring or fixing clip. 6 Two fixing holes for mounting. 7 Location for bus jumpers (see mounting on sockets on page 28).
3 (1) The inputs are mixed with the relay's supply, with the outputs being located on the opposite side of the socket. (2) The inputs and outputs are separated from the relay supply.
10 5 7
5
Presentation : page 22
22
Relay supply Characteristics : pages 23 and 24
References : pages 25 and 26
Dimensions : pages 27 and 28
Schemes : page 29
Zelio Relay - plug-in relays
Characteristics
RXM miniature relays
General characteristics Conforming to standards Product certifications Ambient air temperature around the device
Storage Operation Vibration resistance In operation conforming to IEC/EN 60068-2-6 Not operating Degree of protection Conforming to IEC/EN 60529 Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position
IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n° 14 UL, CSA - 40… + 85 - 40… + 55 3 gn (10...150 Hz/± 1 mm / 5g/5 cycles) 5 gn (10...150 Hz/± 1 mm / 5g/5 cycles) IP 40 15 gn 15 gn RT I Any
°C °C
1 2
Insulation characteristics Rated insulation voltage (Ui) Rated impulse withstand voltage (Uimp) Dielectric strength Between coil and (rms voltage) Between poles Between s
V kV aV aV aV
250 (IEC), 300 (UL, CSA) 4 (1.2/50 ms) 1550 1550 1500
RXM 3ABppp 3 C/O
RXM 4ABppp 4 C/O
A
RXM 2ABppp 2 C/O AgNi 12
10
6
10 5 10
6 3 6
10 / 250 a V 10 / 28 c V 2500 280
6 / 250 a V 6 / 28 c V 1500 168
3
characteristics Relay type Number and type of s materials Conventional thermal current (Ith) Rated operational current in utilisation categories AC-1 and DC-1
For ambient temperature y 55 °C Conforming to IEC "C" “O” Conforming to UL Minimum Maximum Minimum
Switching capacity
Maximum
Maximum operating rate In operating cycles
Minimum No-load Under load
Utilisation coefficient Mechanical durability
In millions of operating cycles
12 6 12 10 a/c 250 (IEC) 17 12 / 250 a V 12 / 28 c V 3000 336 170 18 000 1200 20 % 10
Electrical durability In millions of operating cycles
Resistive load Inductive load
0.1 See curves below
Nominal load (resistive) a c
107
106
D C
105 0
A
A RXM 2ABppp
1 0, 0,6 0,5
B RXM 3ABppp
6
8
3
0,4
0,3
C RXM 4ABppp
5 3 / 250 a V 3 / 28 c V 750 84 15
10 6
1
A D
3
5
Maximum switching capacity on resistive load c
B
1 2 Switching capacity (kVA)
2 1 3 3
0,1
1
0,6
0,4
4
7
Reduction coefficient for inductive load a (depending on power factor cos j) Reduction coefficient (A)
Durability (Number of operating cycles)
Electrical durability of s Resistive load a
mA V V A A VA W mW
Current c
Switching current Switching voltage
RXM 4GBppp 4 C/O low level AgAu - bifurcated 3
0,2
0
B
C
28 50
100
150
9
200 250 Voltage c
D RXM 4GBppp
Durability (inductive load) = durability (resistive load) x reduction coefficient.
10
23
Zelio Relay - plug-in relays
Characteristics (continued)
Coil characteristics
1
RXM miniature relays
a
Average consumption
c
Drop-out voltage threshold
a
Operating time (response time)
Between coil energisation and making of the On-delay
a
Between coil de-energisation and making of the Off-delay
a
2
VA
1.2
W
0.9 u 0.15 Uc
c c
c
Control circuit voltage Uc
u 0.1 Uc ms
20
ms
20
ms
20
ms
20
V
12
24
48
110
120
125
220
230
240
JD
BD
ED
FD
–
GD
MD
–
–
Relay control voltage codes d.c. supply
3
Average resistance at 20 °C ± 10%
W
160
650
2600
11 000
–
11 000
14 000
–
–
Operating voltage limits
Min.
V
9.6
19.2
38.4
88
–
100
176
–
–
Max.
V
13.2
26.4
52.8
121
–
138
242
–
–
–
B7
E7
F7
–
–
P7
U7
Relay control voltage codes a.c. supply
Average resistance at 20 °C ± 15%
W
–
180
770
–
4430
–
–
15 000
15 500
Operating voltage limits
Min.
V
–
19.2
38.4
–
96
–
–
184
192
Max.
V
–
26.4
52.8
–
132
–
–
253
264
Socket characteristics
4 5
Socket type
RXZ E2S108M RXZ E2S111M RXZ E2S114M RXZ E2M114M
RXZ E2M114
Relay types used
RXM 2ppppp
RXM 2ppppp (1) RXM 4ppppp
terminal arrangement Wire connection method
Separate Connector
Product certifications Conforming to standards
UL, CSA IEC 61984, e
Electrical characteristics
7 8 9 10
RXM 4ppppp
Screw clamp terminals
A V
12 250 (IEC)
Between adjacent output s Between input and output s Between s and 5 rail
Vrms Vrms Vrms
2500 2500 2500
Ambient air temperature around the device
°C °C
- 40…+ 55 - 40…+ 85 IP 20 0.5…2.5 mm2 - AWG 20…AWG 14
General characteristics
Operation Storage Degree of protection Conforming to IEC/EN 60529 Cabling Solid cable 1 conductor without cable end 2 conductors Flexible cable 1 conductor with cable end 2 conductors Maximum tightening torque / Screw size Mounting Fixing on 5 rail Terminal referencing Bus jumper (Ith: 5 A) Compatibility with the plastic maintaining clamp Compatibility with the metal maintaining clamp Protection module Clip-in legends Wire connection method
RXM 2ppppp (1) RXM 4ppppp Mixed
Conventional thermal current (Ith) Maximum operating voltage
Insulation characteristics
6
RXM 3ppppp
10
0.5… 1.5 mm2 AWG 20…AWG 16
0.5…1.5 mm2 - AWG 20…AWG 16 0.25…2.5 mm2 - AWG 22…AWG 14
Nm
0.25…1 mm2 - AWG 22…AWG 17 1 / M3 screw On 35 mm 5 rail / on By red plastic clip IEC, NEMA Yes Yes Yes All RXM 040W, RXM 041pp, RXM 021pp Yes Screw connector
0.25…1 mm2 AWG 22…AWG 17
By metal compression spring
By red plastic clip
No
No Screw clamp terminals
(1) When mounting relay RXM 2ppppp on socket RXZ E2Mpppp, the thermal current must not exceed 10 A.
Presentation : page 22
24
Characteristics : pages 23 and 24
References : pages 25 and 26
Dimensions : pages 27 and 28
Schemes : page 29
Zelio Relay - plug-in relays
References
RXM miniature relays
Miniature relays without LED (sold in lots of 10) Control circuit voltage
Number and type of s - Thermal current (Ith) 2 C/O - 12 A Unit reference
106658
V
RXM pAB1F7
3 C/O - 10 A Weight
Unit reference
kg
4 C/O - 6 A Weight
Unit reference
kg
Weight kg
c 12
RXM 2AB1JD
0.037
RXM 3AB1JD
0.037
RXM 4AB1JD
0.037
c 24
RXM 2AB1BD
0.037
RXM 3AB1BD
0.037
RXM 4AB1BD
0.037
c 48
RXM 2AB1ED
0.037
RXM 3AB1ED
0.037
RXM 4AB1ED
0.037
c 110
RXM 2AB1FD
0.037
RXM 3AB1FD
0.037
RXM 4AB1FD
0.037
c 220
–
–
RXM 4AB1MD
0.037
a 24
RXM 2AB1B7
0.037
RXM 3AB1B7
0.037
RXM 4AB1B7
0.037
a 48
RXM 2AB1E7
0.037
RXM 3AB1E7
0.037
RXM 4AB1E7
0.037
a 120
RXM 2AB1F7
0.037
RXM 3AB1F7
0.037
RXM 4AB1F7
0.037
a 230
RXM 2AB1P7
0.037
RXM 3AB1P7
0.037
RXM 4AB1P7
0.037
a 240
–
–
RXM 4AB1U7
0.037
–
–
–
–
1 2 3
106657
Miniature relays with LED (sold in lots of 10)
RXM pAB2F7
c 12
RXM 2AB2JD
0.037
RXM 3AB2JD
0.037
RXM 4AB2JD
0.037
c 24
RXM 2AB2BD
0.037
RXM 3AB2BD
0.037
RXM 4AB2BD
0.037
c 48
RXM 2AB2ED
0.037
RXM 3AB2ED
0.037
RXM 4AB2ED
0.037
c 110
RXM 2AB2FD
0.037
RXM 3AB2FD
0.037
RXM 4AB2FD
0.037
c 125
–
–
RXM 4AB2GD
0.037
a 24
RXM 2AB2B7
0.037
RXM 3AB2B7
0.037
RXM 4AB2B7
0.037
a 48
RXM 2AB2E7
0.037
RXM 3AB2E7
0.037
RXM 4AB2E7
0.037
a 120
RXM 2AB2F7
0.037
RXM 3AB2F7
0.037
RXM 4AB2F7
0.037
a 230
RXM 2AB2P7
0.037
RXM 3AB2P7
0.037
RXM 4AB2P7
0.037
–
–
Miniature relays with low level s, without LED (sold in lots of 10) Control circuit voltage
4 C/O - 3 A
V
106558
5
Number and type of s Thermal current (Ith) Unit reference
RXM 4GB1F7
4
Weight kg
c 12
RXM 4GB1JD
0.037
c 24
RXM 4GB1BD
0.037
c 48
RXM 4GB1ED
0.037
c 110
RXM 4GB1FD
0.037
a 24
RXM 4GB1B7
0.037
a 48
RXM 4GB1E7
0.037
a 120
RXM 4GB1F7
0.037
a 230
RXM 4GB1P7
0.037
c 12
RXM 4GB2JD
0.037
c 24
RXM 4GB2BD
0.037
c 48
RXM 4GB2ED
0.037
c 110
RXM 4GB2FD
0.037
a 24
RXM 4GB2B7
0.037
a 48
RXM 4GB2E7
0.037
a 120
RXM 4GB2F7
0.037
a 230
RXM 4GB2P7
0.037
a 240
RXM 4GB2U7
0.037
6 7
106657
Miniature relays with low level s, with LED (sold in lots of 10)
RXM 4GB2F7
8 9 10
25
References (continued)
Control circuit voltage
2 RXZ E2M114M + Relais RXM 4AB2F7
3
RXM miniature relays
Miniature relays without LED (sold in lots of 100)
106016
1
Zelio Relay - plug-in relays
V c 12 c 24 c 48 c 110 c 220
Number and type of s - Thermal current (Ith) 2 C/O - 12 A Unit Weight reference kg – – RXM 2AB1BDTQ 0.037 – – – – – –
a 24 a 48 a 120 a 230
RXM 2AB1B7TQ – RXM 2AB1F7TQ RXM 2AB1P7TQ
Miniature relays with LED (sold in lots of 100)
106017
c 24 a 24 a 230
– RXM 2AB2B7TQ RXM 2AB2P7TQ
4 C/O - 6 A Unit reference
Weight
RXM 4AB1JDTQ RXM 4AB1BDTQ RXM 4AB1EDTQ RXM 4AB1FDTQ RXM 4AB1MDTQ
kg 0.036 0.036 0.036 0.036 0.036
0.037 – 0.037 0.037
RXM 4AB1B7TQ RXM 4AB1E7TQ RXM 4AB1F7TQ RXM 4AB1P7TQ
0.036 0.036 0.036 0.036
– 0.037 0.037
RXM 4AB2BDTQ RXM 4AB2B7TQ RXM 4AB2P7TQ
0.036 0.036 0.036
Sockets
4
terminal arrangement Mixed
Connection
Relay type
Sold in lots of 10
Unit reference RXZ E2M114 (1)
Screw clamp terminals
RXM 2pppp (3) RXM 4pppp RXM 2pppp (3) RXM 4pppp RXM 2pppp RXM 3pppp RXM 4pppp
10
RXZ E2M114M (1)
0.056
10 10 10
RXZ E2S108M (2) RXZ E2S111M (1)
0.058 0.066 0.070
For use with
Sold in lots of
Unit reference
V c 6...250
All sockets
20
RXM 040W
kg 0.003
RC circuit
a 24...60 a 110...240
All sockets All sockets
20 20
RXM 041BN7 RXM 041FU7
0.010 0.010
Varistor
a/c 6...24 a/c 24...60 a/c 110...240
All sockets All sockets All sockets
20 20 20
RXM 021RB RXM 021BN RXM 021FP
0.030 0.030 0.030
Screw connector Separate
Screw connector
5
RXZ E2S114M (1)
Weight kg 0.048
Protection modules RXZ E2S114M + Relais RXM 4AB2F7
Description
Diode
106018
6 7
RXM 041pp7
Weight
Timing relays Description 535195
2 or 4 timed C/O s (function A)
8
For use with Sockets RXZ Eppppp
Unit reference RE XL2pp (4) RE XL4pp (4)
Weight kg – –
Weight kg 0.001 0.005 0.005
Accessories Description
536484
RE XL4pp
9
Voltage
RXZ 400
Metal maintaining clamp Plastic maintaining clamp Bus jumper 2-pole (Ith: 5 A) Mounting adapter for 5 rails (5) Mounting adapter with fixing lugs for Clip-in legends
For use with All sockets All sockets All sockets with separate s
Sold in lots of 10 10 10
Unit reference RXZ 400 RXZ R335
All relays
10
RXZ E2DA
0.004
All relays
10
RXZ E2FA
0.002
All relays (sheet of 108 legends) All sockets except RXZ E2M114
10 10
RXZ L520 RXZ L420
0.080 0.001
RXZ S2
(1) Thermal current Ith: 10 A (2) Thermal current Ith: 12 A (3) When mounting relay RXM 2ppppp on socket RXZ E2Mpppp, the thermal current must not exceed 10 A. (4) Please consult the "Zelio Time timing relays" catalogue. (5) Test button becomes inaccessible.
10 Presentation : page 22
26
Characteristics : pages 23 and 24
References : pages 25 and 26
Dimensions : pages 27 and 28
Schemes : page 29
Zelio Relay - plug-in relays
Dimensions
RXM miniature relays
Dimensions
Miniature relays RXM pppppp Common view
RXM 2 Pin side view
RXM 3
21 40
4,4 4,4 4,4
2
27
6,3 6,3 4,2 4,2
6,6 6,6
9
1
RXM 4
6
21
2,5
21 2,5
2,5
2,5
13,2
4,4 2,5
13,2
2,5 13,2
3
Sockets RXZ E2M114
RXZ E2M114M
40
43 19
25,5
17
(4) 14 5
32
22
12
4
3
2
1
11
(2)
A2 14
9 23 7
30
A1 13
9
39,5
34
8
7
24 14 6
42
32
22 12
4
3
2
1
(2)
(3)
A2 14
A1
41
31
21
41
31
21
13 11
12
11
10
12
11
10
9
(4)
21
50 7
30
4
5
80
61
(1)
44
5
40
24 6
44 8 42
3,5
(3)
79
(1)
34 7
23,5
67
6
27
69
Common side view
RXZ E2S108M
RXZ E2S111M
RXZ E2S114M
61
7
19
44 8
14 5
34
42 4
12 1
32
21 9
8 24
6
31
21 11
7
12 44
11 34
10 9 24 14
4
8 42
7 32
6 5 22 12
1
4
3
2
14 5
22 3
41
11
12 2
1
8
70
A2
A1
14
13
38
38
38
(5) 29
23 7
31
(2)
3,5
(3)
11 9
79
(1)
41 12
A2
A1 14
13
A2
A1 14
9
13
23,5
23,5
23,5
27
27
27
(1) Relays (2) Protection module (3) Maintaining clamp (4) 2 elongated holes Ø 3.5 x 6.5 (5) 2 bus jumpers
10
27
Zelio Relay - plug-in relays
Dimensions (continued)
RXM miniature relays
Dimensions (continued)
Plastic clamp and clip-in legends RXZ R335
RXZ L420
57 12
26,5 (1)
94,5
27
2
Mounting on all sockets (1)
14,2
1
3 81
4
(1) Clip-in legends for all sockets except RXZ E2M114
Bus jumper
Metal clamp
RXZ S2
RXZ 400
7,3
22
25
2,2
5
Mounting on sockets with separate s (view from below) Example of bus jumper mounting on sockets
22
(1)
(1)
2,3
42
(2)
(2)
0,
6 (1) 2 bus jumpers (polarity A2) (2) 2 bus jumpers (polarity A1)
RXZ E2FA
38
43
38
Mounting adapter for
RXZ E2DA
48
7
Mounting adapter for rails (1)
8 3
3,5
6
3,5 49
4 24
24
23
9
48
4
51
(1) Test button becomes inaccessible
10 Presentation : page 22
28
Characteristics : pages 23 and 24
References : pages 25 and 26
Dimensions : pages 27 and 28
Schemes : page 29
Zelio Relay - plug-in relays
Schemes
RXM miniature relays
Schemes
Miniature relays
A2 A1
44
42
4
1
2
3
1
2
3
4
12 5
42 8
12
22
32
4
5
6
12 5
22 6
32 7
42 8
14 9
44 12
14 7
24 8
34 9
14 9
24 10
34 11
44 12
11 13
41 14
21
21
31
41 14
A2
31 14
11 13
A1
11 13
A2
41
34
32
1
A1
31
24
22
21
14
12
A2 A1
11
34
32
31
24
22
1
RXM 4ppppp
21
14
12
A2 A1
11
44
42
RXM 3ppppp
41
14 11
12
RXM 2ppppp
A1
2 3
A2
Symbols shown in blue correspond to Nema marking.
Sockets RXZ E2M114
4 42
4
RXZ E2M114M
6 7 34 24 8 5 44 14 3 2 1 32 22 12
8 44
7 6 34 24
5 14
4 42
3 32
1 12 1
2 22
5
5 9
14 A2 12 41
13 A1 11 31
9 11 10 21
14
13
A2 14 41 31 12 11
A1 13 21 10
11 9
6
Symbols shown in blue correspond to Nema marking. RXZ E2S108M
RXZ E2S111M 9 11 5 14
9 31 6 34
8 21 5 24
7 11 4 14
4 42
1 12
3 32
2 22
1 12
A1
A2
14 A2
RXZ E2S114M
12 41 8 44
A1
A2
13 INPUT A1
14 A2
12 41 8 44 4 42
13 INPUT A1
11 31 7 34 3 32
10 21 6 24 2 22
7
A1
A2
14 A2
9 11 5 14 1 12
8
13 INPUT A1
Symbols shown in blue correspond to Nema marking.
Protection modules RXM 040W
RXM 041ppp
RXM 021ppp
– A2
– A2
– A2
+ A1
+ A1
+ A1
9 10
29
Zelio Relay - plug-in relays
1
536294
Presentation
RUM universal relays
Presentation of the range
6
The RUM universal relay range comprises: 1 10 A relays with 2 and 3 C/O s, with cylindrical or flat (Faston type) pins, and 3 A low level relays with 3 C/O s, with cylindrical pins. All these relays have the same dimensions. 2 Sockets with mixed or separate terminals. 3 Protection modules (diode, RC circuit or varistor) or 1 timer module. All these modules are common to all sockets. 4 A metal maintaining clamp for all sockets. 5 A 2-pole bus jumper that can be used on sockets with separate terminals in order to simplify cabling when creating an equipotential link between the coil terminals. 6 Clip-in legends for the sockets.
2
1
2
4 5
3
3
Relay description
106663
6
1 Spring return pushbutton for testing the s (green: c, red: a). 2 Mechanical “relay status” indicator. 3 Removable lock-down door enabling forced maintaining of the s for test sequences or maintenance purposes. During operation, this lock-down door must always be in the closed position. 4 LED (depending on version) indicating the relay status. 5 Removable legend for relay identification. 6 Area by which the product can be easily gripped. 7 Eight or eleven cylindrical pins. 8 Eight or eleven flat (Faston type) pins
1 2 3 4
4 5
5
1
106022
6
Socket description
Outputs
Sockets with mixed terminals (1) 1 Connection by screw connector. 2 Eight or eleven female s for the relay cylindrical pins. 3 Location for protection modules or the timer module. 4 Locking component for metal maintaining clamp. 5 A locating slot for mounting on 5 rail. 6 Two fixing holes for mounting.
2 6 4
7
3 Relay supply
5
8
Inputs Relay suppy
6
9
1
106024
106023
1
Inputs
Sockets with separate terminals (2) 1 Connection by screw connector. Outputs 2 a Eight or eleven female s for the relay cylindrical pins. b Eleven female s for the relay flat pins. 2b 3 Location for protection modules or the timer module. 4 Locking component for metal maintaining clamp. 5 Locating slot for mounting on 5 rail with fixing clip. 4 6 Two fixing holes for mounting. 7 Location for bus jumpers (see mounting on sockets on page 36). 3 Inputs
Outputs
4 2a 3
10
57
5
Relay supply
Characteristics : page 31
30
57
5 Relay supply
References : pages 33 and 34
(1) The inputs are mixed with the relay's supply, with the outputs being located on the opposite side of the socket. (2) The inputs and outputs are separated from the relay supply. Dimensions : page 35
Schemes : page 37
Setting-up : page 39
Zelio Relay - plug-in relays
Characteristics
RUM universal relays
General characteristics Conforming to standards Product certifications Ambient air temperature around the device
Storage Operation Vibration resistance In operation conforming to IEC/EN 60068-2-6 Not operating Degree of protection Conforming to IEC/EN 60529 Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position
IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n° 14 UL, CSA - 40… + 85 - 40… + 55 3 gn (10...150 Hz/± 1 mm / 5g/5 cycles) 4 gn (10...150 Hz/± 1 mm / 5g/5 cycles) IP 40 10 gn 10 gn RT I Any
°C °C
1 2
Insulation characteristics Rated insulation voltage (Ui)
V
250 (IEC), 300 (UL, CSA)
Rated impulse withstand voltage (Uimp)
kV
4 (1.2/50 µs)
Dielectric strength (rms voltage)
aV aV aV
1550 1550 1500
Conforming to IEC/EN 60947 Between coil and Between poles Between s
3
characteristics Relay type Number and type of s
RUM F2ppp 2 C/O
materials
RUM F3ppp 3 C/O
RUM C2ppp 2 C/O
RUM C3App 3 C/O
RUM C3Gpp 3 C/O low level
.
AgNi
AgAu
A
10
3
"C"
A
10
2
“O”
A
5
1
Conventional thermal current (Ith)
For ambient temperature y 55°C
Rated operational current in utilisation categories AC-1 and DC-1
Conforming to IEC Conforming to UL
A
16 / a 277 V 12 / c 28 V
3
Switching current
Minimum
mA
10
3
Switching voltage
Maximum
V
a/c 250 (IEC)
Minimum
V
17
5
A
10 / 250 a V
3 / 250 a V
A
10 / 28 c V
3 / 28 c V
VA
2500
750
W
280
84
mW
170
15
Nominal load (resistive) Switching capacity
Maximum
a c
Minimum Maximum operating rate In operating cycles/hour
No-load
18 000
Under load
1200
Utilisation coefficient In millions of operating cycles
5
Electrical durability In millions of operating cycles
Resistive load
0.1
Inductive load
See curves below
106
Maximum switching capacity on resistive load c Current c
107
1 0, 0,6 0,5
8
10 3
0,4
B
1
A
9
A
105 0
6 7
Reduction coefficient for inductive load a (depending on power factor cos ϕ) Reduction coefficient (A)
Durability (Number of operating cycles)
Electrical durability of s Resistive load a
B
5
20 %
Mechanical durability
4
1 2 3 Switching capacity (kVA)
A RUM Fppppp, RUM C2ppp, RUM C3Appp
0,3
1
0,6
0,4
0,2
0,1
0
28 50
100
150
200 250 Voltage c
B RUM C3Gppp
10
Durability (inductive load) = durability (resistive load) x reduction coefficient.
31
Zelio Relay - plug-in relays
Characteristics (continued)
Coil characteristics
1
RUM universal relays
a
Average consumption
c
Drop-out voltage threshold
a
Operating time (response time)
Between coil energisation and making of the On-delay
a
Between coil de-energisation and making of the Off-delay
a
2
VA
2...3
W
1.4 u 0.15 Uc
c
u 0.1 Uc ms
20
ms
20
ms
20
ms
20
V
12
24
48
60
110
120
125
220
230
JD
BD
ED
ND
FD
–
GD
MD
–
Ω
120
470
1800
2790
10 000
–
10 000
3700
–
Min.
V
9.6
19.2
38.4
48
88
–
100
176
–
Max.
V
13.2
26.4
52.8
66
121
–
137.5
242
–
–
B7
E7
–
–
F7
–
–
P7
Ω
–
72
290
–
–
1700
–
–
7200
Min.
V
–
19.2
38.4
–
–
96
–
–
184
Max.
V
–
26.4
52.8
–
–
132
–
–
253
c
c
Control circuit voltage Uc Relay control voltage codes
3
d.c. supply
Average resistance at 20 °C ± 10% Operating voltage limits
Relay control voltage codes a.c. supply
Average resistance at 20 °C ± 15% Operating voltage limits
4 5
Socket characteristics Socket type
RUZ C2M
RUZ C3M
RUZ SC2M
RUZ SC3M
RUZ SF3M
Relay types used
RUM C2ppppp
RUM C3ppppp
RUM C2ppppp
RUM C3ppppp
RUM Fppppp
terminal arrangement
Mixed
Wire connection method
Connector
Product certifications
UL, CSA
Conforming to standards
IEC 61984, e
Electrical characteristics
Conventional thermal current (Ith)
A
10
Maximum operating voltage
V
250 (IEC)
Between adjacent output s
Vrms
2500
Between input and output s
Vrms
2500
Between s and 5 rail
Vrms
2500
Insulation characteristics
6
General characteristics
7
9
12
Ambient air temperature around the device
Operation
°C
- 40…+ 55
Storage
°C
- 40…+ 85
Degree of protection
Conforming to IEC/EN 60529
IP 20
Cabling
Solid cable without cable end
1 conductor
0.5…2.5 mm2 - AWG 20…AWG 14
2 conductors
0.5…1.5 mm2 - AWG 20…AWG 16
Flexible cable with cable end
1 conductor
0.25…2.5 mm2 - AWG 22…AWG 14
2 conductors
Maximum tightening torque / Screw size
8
Separate
0.25…1 mm2 - AWG 22…AWG 17 Nm
1 / M3.3 screw
Mounting
On 35 mm 5 rail / on
Fixing on 5 rail
By red plastic clip
Terminal referencing
IEC, NEMA
Bus jumper (Ith: 5 A)
No
Compatibility with the metal maintaining clamp
Yes
Timer module
Yes
Protection module
All RUW 24ppp
Clip-in legends Wire connection method
Yes
No
Yes
Screw connector
10 Characteristics : page 31
32
References : pages 33 and 34
Dimensions : page 35
Schemes : page 37
Setting-up : page 39
Zelio Relay - plug-in relays
References
RUM universal relays
References
Relays for standard applications, without LED (sold in lots of 10)
106664
Pins
Cylindrical
RUM ppAB1F7
Flat (Faston type)
Control circuit voltage
1
V c 12 c 24 c 48 c 60 c 110 c 125 c 220
Number and type of s - Thermal current (Ith) 2 C/O - 10 A 3 C/O - 10 A Unit Weight Unit reference reference kg RUM C2AB1JD 0.085 RUM C3AB1JD RUM C2AB1BD 0.085 RUM C3AB1BD RUM C2AB1ED 0.085 RUM C3AB1ED – – RUM C3AB1ND RUM C2AB1FD 0.085 RUM C3AB1FD – – RUM C3AB1GD – – RUM C3AB1MD
a 24 a 48 a 120 a 230
RUM C2AB1B7 RUM C2AB1E7 RUM C2AB1F7 RUM C2AB1P7
0.085 0.085 0.085 0.085
RUM C3AB1B7 RUM C3AB1E7 RUM C3AB1F7 RUM C3AB1P7
0.088 0.088 0.088 0.088
c 12 c 24 c 48 c 110
RUM F2AB1JD RUM F2AB1BD RUM F2AB1ED RUM F2AB1FD
0.080 0.080 0.080 0.080
RUM F3AB1JD RUM F3AB1BD RUM F3AB1ED RUM F3AB1FD
0.082 0.082 0.082 0.082
a 24 a 48 a 120 a 230
RUM F2AB1B7 RUM F2AB1E7 RUM F2AB1F7 RUM F2AB1P7
0.080 0.080 0.080 0.080
RUM F3AB1B7 RUM F3AB1E7 RUM F3AB1F7 RUM F3AB1P7
0.082 0.082 0.082 0.082
Weight kg 0.088 0.088 0.088 0.088 0.088 0.088 0.088
Relays for standard applications, with LED (sold in lots of 10) 106663
Cylindrical
RUM ppAB2F7
Flat (Faston type)
c 12 c 24 c 48 c 60 c 110 c 125
RUM C2AB2JD RUM C2AB2BD RUM C2AB2ED – RUM C2AB2FD –
0.085 0.085 0.085 – 0.085 –
RUM C3AB2JD RUM C3AB2BD RUM C3AB2ED RUM C3AB2ND RUM C3AB2FD RUM C3AB2GD
0.088 0.088 0.088 0.088 0.088 0.088
a 24 a 48 a 120 a 230
RUM C2AB2B7 RUM C2AB2E7 RUM C2AB2F7 RUM C2AB2P7
0.085 0.085 0.085 0.085
RUM C3AB2B7 RUM C3AB2E7 RUM C3AB2F7 RUM C3AB2P7
0.088 0.088 0.088 0.088
c 12 c 24 c 48 c 110
RUM F2AB2JD RUM F2AB2BD RUM F2AB2ED RUM F2AB2FD
0.084 0.084 0.084 0.084
RUM F3AB2JD RUM F3AB2BD RUM F3AB2ED RUM F3AB2FD
0.082 0.082 0.082 0.082
a 24 a 48 a 120 a 230
RUM F2AB2B7 RUM F2AB2E7 RUM F2AB2F7 RUM F2AB2P7
0.084 0.084 0.084 0.084
RUM F3AB2B7 RUM F3AB2E7
0.082 0.082 0.082 0.082
RUM F3AB2F7 RUM F3AB2P7
Relays with low level s, with LED (sold in lots of 10) Pins
Cylindrical
Control circuit voltage
V c 24 c 48
Number and type of s Thermal current (Ith) 3 C/O - 3 A Unit Weight reference kg RUM C3GB2BD 0.086 RUM C3GB2ED 0.086
a 24 a 48 a 120 a 230
RUM C3GB2B7 RUM C3GB2E7 RUM C3GB2F7 RUM C3GB2P7
0.086 0.086 0.086 0.086
33
2 3 4 5 6 7 8 9 10
References (continued)
Sockets
terminal arrangement Mixed
Separate
2
Connection
Relay type
Sold in lots of
Unit reference
Screw connector
RUM C2ppppp
10
RUZ C2M
0.054
RUM C3ppppp
10
RUZ C3M
0.054
RUM C2ppppp
10
RUZ SC2M
0.095
RUM C3ppppp
10
RUZ SC3M
0.100
RUM F2pppp
10
RUZ SF3M
0.095
Sold in lots of
Unit reference
Screw connector
Protection modules Description
For use with
Voltage
106027
V
RUW 241P7
4
Weight kg
Diode
All sockets
c 6…250
10
RUW 240BD
0.004
RC circuit
All sockets
a 110…240
10
RUW 241P7
0.004
Varistor
All sockets
a/c 24
10
RUW 242B7
0.004
a/c 240
10
RUW 242P7
0.004
Timer module Description
For use with
Voltage
Reference
V Multifunction
106028
5
RUW 101MW
All sockets
Weight kg
RUW 101MW
a/c 24… 240
0.020
Timing relays Description
For use with
Reference
2 timed C/O s On sockets RUZ M (single-function or multifunction)
RE 48A pp (1)
Weight kg –
Accessories
6 536485
Description
535203
RUZ C200
7
Weight kg
RUM F3pppp RUZ C3M + relais RUM C3ppppp
3
RUM universal relays
References (continued)
106025
1
Zelio Relay - plug-in relays
For use with
Sold in lots of
Unit reference
Metal maintaining clamp
All sockets
10
RUZC200
0.001
Bus jumper 2-pole (Ith : 5 A)
All sockets with separate s
10
RUZ S2
0.005
Clip-in legends
All relays (sheet of 108 legends)
10
RXZ L520
0.080
All sockets with separate s
10
RUZ L420
0.001
RUZ S2
(1) Please consult the "Zelio Time timing relays" catalogue.
Characteristics : page 31
References : pages 33 and 34
8 9 10
34
Dimensions : page 35
Schemes : page 37
Setting-up : page 39
Weight kg
Zelio Relay - plug-in relays
Dimensions
RUM universal relays
Dimensions
Universal relays
1
RUM Fpp
9
55
35
35
RUM p
35
9
53
2
35
Sockets Common side view
RUZ C2M
RUZ C3M
22 24
22
6
4
5
(1)
34
32
24
22
14
12
9
8
7
5
3
4
3
4
6
3
8
7
2
9
(2)
A2
21
11
7
4
27 89
3
1
2 1
INPUT A2 10 A2 A2
A1
8
10
2
4
4
11
INPUT A1 2
A2 7
63
1
3
5
10
37
37
8 INPUT A2 7
6
7
74
(3)
12 14
5
31 10
21 11
30
30
38
38
INPUT A1 2 11
6
A1 1
5
2
93 RUZ SC2M
6
RUZ SC3M
63
45 19
19
24 6
21 8
92
5
12 4 14 3
4
6 7
(3)
40 102
105
(2) A1 2
34 9
24 7
14 3
32
22
12
8
5
4
30
29
36
75
7 8
A2 10
(4) 4
4
29 75
11 1
1
A2 7
(4)
21 6
7 6 5 8 4 9 3 10 2 11 1
2 8
(2)
Ø4
(1)
3
31 11
40
Ø4
(1) (3)
11 1
92
22 5
A1 2
32 36
9
102 105
(1) Relays (2) Protection module (3) Maintaining clamp (4) 2 bus jumpers
10
35
Zelio Relay - plug-in relays
Dimensions (continued)
RUM universal relays
Dimensions (continued)
1
Sockets (continued) RUZ SF3M
63
2
21 9
31 8
11 7
24 6
34 5
14 4
22
32
12
3
2
1
(1) 92
(3)
3
(2) A2 B
(4) 46
29
4
27
A1 A
36
104
4
(1) Relays (2) Protection module (3) Maintaining clamp (4) 2 bus jumpers
Metal maintaining clamps and plastic legends Mounting
35
5
RUZ C200
108
0,
RUZ L420
32 12
7
59,6
14,2
6
8
Bus jumper RUZ S2
Mounting on sockets with separate s (view from below) Example of bus jumper mounting on sockets
(1)
(1)
(2)
(2)
8,5
9
3,3
35,4
32 2,3
10
(1) 2 bus jumpers (polarity A2) (2) 2 bus jumpers (polarity A1)
Characteristics : page 31
36
References : pages 33 and 34
Dimensions : page 35
Schemes : page 37
Setting-up : page 39
Zelio Relay - plug-in relays
Schemes
RUM universal relays
Schemes
Universal relays
1 24
A2
21
A1
34
22
31
14
32
12
A2 A1
11
34
RUM F3ABppp
31
24
32
21
14
22
12
A2 A1
11
24
RUM C3ppppp
21
14
22
11
12
RUM p2ABppp
2 RUM C2ABppp
RUM F2ABppp
12 4 14
A1
5
22
3
6
2
7
+
11
1
24
A2
21
RUM C3ppppp
1
3
12 4
22 6
14 7
24 9
11 A (+)
21 B( )
A1
A2
22 12
RUM F3ABppp
21 6
5
7
24
4
14 3 A1
32
9 34 2
+
10 11 31
1 11
A2
1
2
3
12 4
32 5
22 6
14 7
34
24 9
11 A (+)
31
21 B( )
A1
3
A2
4
Symbols shown in blue correspond to Nema marking.
Sockets RUZ C2M 6
RUZ C3M
RUZ SC2M
5
4
3
9
8
7
5
3
24 22
12
14
34
32
24
22
14 12
6 7
7 A2
7 A2
5
8
4
1
8 21
6 5 7
3
8
2
9 10
1 11
2 A1
10 10 A2 A2
4
11 31
6 21
4 12 3 14
1 11 8 21
6 21 7 24 5 22
11 31 8 32 9 34
4 5
3 11 1
RUZ SC3M
5 22 6 24
4
7
1 11
2 A1
7 A2
8
8
3
6
2
1
7
9 10
2
2 A1
10 A2
6 5
5
1 11 4 12 3 14
4
6
3 11 1
2
2 A1
7
Symbols shown in blue correspond to Nema marking. RUZ SF3M 9 21 6 24
8 31 5 34
7 11 4 14
3 22
2 32
1 12
B A2
8 9
A A1
Symbols shown in blue correspond to Nema marking.
10
37
Zelio Relay - plug-in relays
Schemes (continued)
RUM universal relays
Schemes (continued)
1
Protection modules RUW 240BD
RUW 241P7
RUW 242pp
– A2
– A2
– A2
+ A1
+ A1
+ A1
2 3 4 5 6 7 8 9 10 Characteristics : page 31
38
References : pages 33 and 34
Dimensions : page 35
Schemes : page 37
Setting-up : page 39
Zelio Relay - plug-in relays
Setting-up
RUM universal relays
Multifunction timer module RUW 101MW Programming
Timing range selection
1
Function Timing range selection selection 0.1…1 s
0.1…10 s
0.1…1 min
1…10 min
0.1…1 h
0.1…1 day
1…10 h
1…10 days
2 Function selection Series control
Monostable with maintained control Wu
Series control
Flashing relay, starting On-delay phase Bi
Series control
Flashing relay, starting Off-delay phase Bp
Series control
Off-delay timer R
t
R t
t t
5
U .1/.4 .1/.2
Monostable, starting on de-energisation Wa
On-delay Timer Es
Control by external (S)
t t
U
U S
t
U
R
S
A2
7
t
U S .1/.4 .1/.2
Control by external (S)
6
S
.1/.4 .1/.2
Control by external (S)
4
U .1/.4 .1/.2
.1/.4 .1/.2
Monostable with pulse control Ws
3
U .1/.4 .1/.2
Control by external (S)
U
U .1/.4 .1/.2
Control scheme
B1
On-delay Timer E
Function diagram
A1
Control
A2
Function
A1
Selection
8
t
U S .1/.4 .1/.2
9
t
Power off
open
U : voltage
S : external control
Power on
closed
R : relay RUM ppp
t : adjustable time delay
10
39
Zelio Relay - plug-in relays
Presentation
Presentation of the range
106035
1
RPM power relays
2
1
2
A metal maintaining clamp for single- relays.
3
3 1
Relay description
1 Spring return pushbutton for testing the s (green: c, red: a). 2 Mechanical “relay status” indicator. 3 Removable lock-down door enabling forced maintaining of the s for test sequences or maintenance purposes. During operation, this lock-down door must always be in the closed position. 4 LED (depending on version) indicating the relay status. 5 Removable legend for relay identification. 6 Four notches for rail mounting adapter or mounting adapter with fixing lugs. 7 Five, eight, eleven or fourteen Faston type pins. 8 Area by which the product can be easily gripped. 9 Mounting adapter enabling direct mounting of the relay on a . 10 Mounting adapter enabling direct mounting of the relay on a 5 rail.
106669
8
4
The RPM power relay range comprises: 1 15 A relays with 1, 2, 3 and 4 C/O s. 2 Sockets with mixed terminals. 3 Protection modules (diode, RC circuit or varistor) or 1 timer module. All these modules are common to all the sockets except for the timer module, which can only be used on the 3-pole or 4-pole sockets.
2 3 4 5
7 6
5 106674
9
106673
106672
9
6 7 10
106040
7
Socket description
5 1
Outputs
2
8
Sockets with mixed terminals (1) 1 Connection by screw clamp terminals. 2 Five, eight, eleven or fourteen female s for the relay pins. 3 Location for protection modules or the timer module. 4 Locating slot for mounting on rail with fixing clip. 5 Two or four fixing holes for mounting. (1) The inputs are mixed with the relay's supply, with the outputs being located on the opposite side of the socket.
3
Relay supply
9 4
Inputs
10 Characteristics : page 41
40
References : page 43
Dimensions : page45
Schemes : page 47
Zelio Relay - plug-in relays
Characteristics
RPM power relays
General characteristics Conforming to standards Product certifications Ambient air temperature around the device
Storage Operation Vibration resistance In operation conforming to IEC/EN 60068-2-6 Not operating Degree of protection Conforming to IEC/EN 60529 Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position
IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n° 14 UL, CSA - 40… + 85 - 40… + 55 3 gn (10...150 Hz/± 1 mm / 5g/5 cycles) 5 gn (10...150 Hz/± 1 mm / 5g/5 cycles) IP 40 15 gn 15 gn RT I Any
°C °C
1 2
Insulation characteristics Rated insulation voltage (Ui) Conforming to IEC/EN 60947 Rated impulse withstand voltage (Uimp) Dielectric strength Between coil and (rms voltage) Between poles Between s
V kV aV aV aV
250 (IEC), 300 (UL, CSA) 4 (1.2/50 µs) 1550 1550 1500
A
RPM 1ppp 1 C/O AgNi 15
3
characteristics Relay type Number and type of s materials Conventional thermal For ambient current (Ith) temperature y 55 °C Rated operational current Conforming to IEC in utilisation categories AC-1 and DC-1 Conforming to UL Switching current Minimum Switching voltage Maximum Minimum Nominal load (resistive)
"C" “O”
Switching capacity
Maximum
a c
Maximum operating rate In operating cycles/hour
Minimum No-load Under load
Electrical durability In millions of operating cycles
106
105
0
1
2
3
4 3,75 Switching capacity (kVA)
4 5 6
20 % 10 0.1 See curves below
1 0, 0,6 0,5
0,4
0,3
7
0.06
Reduction coefficient for inductive load a (depending on power factor cos ϕ) Reduction coefficient (A)
Durability (Number of operating cycles)
107
RPM 4ppp 4 C/O
15 7.5 15 10 a/c 250 (IEC) 17 15 / 250 a V 15 / 28 c V 3750 420 170 18 000 1200
In millions of operating cycles Resistive load Inductive load
Electrical durability of s Resistive load a
RPM 3ppp 3 C/O
Maximum switching capacity on resistive load c Current c
Utilisation coefficient Mechanical durability
A A A mA V V A A VA W mW
RPM 2ppp 2 C/O
8
15 10
1
0,1
1
0,6
0,4
0,2
0
28 50
100
150
9
200 250 Voltage c
Durability (inductive load) = durability (resistive load) x reduction coefficient.
10
41
Zelio Relay - plug-in relays
Characteristics (continued)
RPM power relays
Coil characteristics
1
Relay type Average consumption
RPM 2ppp 1.2 0.9
RPM 3ppp 1.5 1.7
RPM 4ppp 1.5 2
ms
RPM 1ppp 0.9 0.7 u 0.15 Uc u 0.1 Uc 20
25
25
20
c
ms
20
25
25
20
a
ms
20
c
ms
20
V
12
24
48
110
120
230
RPM 1ppp RPM 2ppp RPM 3ppp RPM 4ppp Min. Max.
Ω Ω Ω Ω V V
JD 180 160 100 96 9.6 13.2
BD 750 650 400 388 19.2 26.4
ED 2600 2600 2600 1550 38.4 52.8
FD 13 100 11 000 8600 7340 88 121
– – – – – – –
– – – – – – –
RPM 1ppp RPM 2ppp RPM 3ppp RPM 4ppp Min. Max.
Ω Ω Ω Ω V V
– – – – – – –
B7 160 180 103 84.3 19.2 26.4
E7 720 770 770 338 38.4 52.8
– – – – – – –
F7 4430 4430 2770 2220 96 132
P7 15 720 15 000 12 000 9120 184 253
Drop-out voltage threshold Operating time (response time)
Between coil energisation and making of the On-delay
2
Between coil de-energisation and making of the Off-delay
a c a c a
VA W
Control circuit voltage Uc
3
Relay control voltage codes d.c. supply Average resistance at 20 °C ± 10%
Operating voltage limits
4
Relay control voltage codes a.c. supply Average resistance at 20 °C ± 15%
Operating voltage limits
5 6 7
Socket characteristics Socket type
RPZ F1
RPZ F2
RPZ F3
RPZ F4
Relay types used
RPM 1ppp
RPM 2ppp
RPM 3ppp
RPM 4ppp
Protection module types used
RXM 02ppp RXM 04ppp
RXM 02ppp RXM 04ppp
RUW 24ppp
RUW 24ppp
terminal arrangement Wire connection method Product certifications Conforming to standards
Electrical characteristics
Conventional thermal current (Ith) Maximum operating voltage
A V
16 250 (IEC)
Between adjacent output s Between input and output s Between s and 5 rail
Vrms Vrms Vrms
2500 2500 2500
Ambient air temperature around the device
°C °C
- 40…+ 55 - 40…+ 85 IP 20 0.5…1.5 mm2 - AWG 20…AWG 16 0.5…2.5 mm2 - AWG 20…AWG 14 0.5…1.5 mm2 - AWG 20…AWG 16 0.5…2.5 mm2 - AWG 20…AWG 14
Insulation characteristics
General characteristics
8 9 10
Mixed Screw clamp terminals UL, CSA IEC 61984, e
Operation Storage Degree of protection Conforming to IEC/EN 60529 Cabling Solid cable 1 conductor without 2 conductors cable end Flexible cable 1 conductor with cable end 2 conductors Maximum tightening torque / Screw size Mounting Fixing on 5 rail Terminal referencing Compatibility with the metal maintaining clamp Timer module Protection module Clip-in legends Wire connection method Screw clamp terminals
Presentation : page 40
42
Characteristics : page 41
Nm
0.25…1 mm2 - AWG 22…AWG 17 0.25…1.5 mm2 - AWG 22…AWG 16 0.25…1 mm2 - AWG 22…AWG 17 0.25…1.5 mm2 - AWG 22…AWG 16 1 / M3 screw 1 / M3.5 screw On 35 mm 5 rail / on By red plastic clip IEC, NEMA Yes No No Yes RXM 040W, RXM 041pp, RXM 021pp RUW 24pp No
References : page 43
Dimensions : page 45
Schemes : page 47
Zelio Relay - plug-in relays
References
RPM power relays
Power relays without LED (sold in lots of 10)
106670
Control circuit voltge V c 12
Number and type of s - Thermal current (Ith) 1 C/O - 15 A 2 C/O - 15 A 3 C/O - 15 A Unit Weight Unit Weight Unit Weight reference reference reference kg kg kg RPM 11JD 0.026 RPM 21JD 0.036 RPM 31JD 0.054
4 C/O - 15 A Unit Weight reference kg 0.071 RPM 41JD
c 24
RPM 11BD
0.026
RPM 21BD
0.036
RPM 31BD
0.054
RPM 41BD
0.071
c 48
RPM 11ED
0.026
RPM 21ED
0.036
RPM 31ED
0.054
RPM 41ED
0.071
c 110
RPM 11FD
0.026
RPM 21FD
0.036
RPM 31FD
0.054
RPM 41FD
0.071
a 24
RPM 11B7
0.026
RPM 21B7
0.036
RPM 31B7
0.054
RPM 41B7
0.071
a 48
RPM 11E7
0.026
RPM 21E7
0.036
RPM 31E7
0.054
RPM 41E7
0.071
a 120
RPM 11F7
0.026
RPM 21F7
0.036
RPM 31F7
0.054
RPM 41F7
0.071
a 230
RPM 11P7
0.026
RPM 21P7
0.036
RPM 31P7
0.054
RPM 41P7
0.071
1 2
RPM 41BD
4
106669
Power relays with LED (sold in lots of 10)
RPM 42BD
3
c 12
RPM 12JD
0.026
RPM 22JD
0.036
RPM 32JD
0.054
RPM 42JD
0.071
c 24
RPM 12BD
0.026
RPM 22BD
0.036
RPM 32BD
0.054
RPM 42BD
0.071
c 48
RPM 12ED
0.026
RPM 22ED
0.036
RPM 32ED
0.054
RPM 42ED
0.071
c 110
RPM 12FD
0.026
RPM 22FD
0.036
RPM 32FD
0.054
RPM 42FD
0.071
a 24
RPM 12B7
0.026
RPM 22B7
0.036
RPM 32B7
0.054
RPM 42B7
0.071
a 48
RPM 12E7
0.026
RPM 22E7
0.036
RPM 32E7
0.054
RPM 42E7
0.071
a 120
RPM 12F7
0.026
RPM 22F7
0.036
RPM 32F7
0.054
RPM 42F7
0.071
a 230
RPM 12P7
0.026
RPM 22P7
0.036
RPM 32P7
0.054
RPM 42P7
0.071
5 6 7 8 9 10
43
References (continued)
terminal arrangement Mixed
Connection
Relay type
Unit reference
RPM 1ppp RPM 2ppp RPM 3ppp
Sold in lots of 10 10 10
RPZ F1 RPZ F2 RPZ F3
Weight kg 0.042 0.054 0.072
Screw clamp terminals
RPM 4ppp
10
RPZ F4
0.094
Voltage
Socket type
Sold in lots of
Unit reference
V c 6...250
RPZ F1RPZ F2
20
RXM 040W
kg 0.003
10
RUW 240BD
0.004
a 24...60
RPZ F3 RPZ F4 RPZ F1RPZ F2
20
RXM 041BN7
0.010
a 110...240
RPZ F1RPZ F2
20
RXM 041FU7
0.010
10
RUW 241P7
0.004
a/c 6...24
RPZ F3 RPZ F4 RPZ F1RPZ F2
20
RXM 021RB
0.030
a/c 24...60
RPZ F1RPZ F2
20
RXM 021BN
0.030
a/c 110...240
RPZ F1RPZ F2
20
RXM 021FP
0.030
a/c 24
RPZ F3 RPZ F4 RPZ F3 RPZ F4
10
RUW 242B7
0.004
10
RUW 242P7
0.004
Protection modules
2
Description
RPZ F2 + relay RPM 22F7
Diode
RC circuit
106044
3
RPM power relays
Sockets
106043
1
Zelio Relay - plug-in relays
RUW 24ppp Varistor
4
a/c 240
5
Timer module (1) Description
106045
Multifunction
6
Weight
Voltage V a/c 24… 240
Reference
RPZ F3 RPZ F4
RUW 101MW
Weight kg 0.020
Accessories Description
For use with RPZ F1
Sold in lots of 20
Unit reference RPZ R235
RPM 1ppp RPM 2ppp RPM 3ppp RPM 4ppp
20 20 20 20
RPZ 1DA RXZ E2DA RPZ 3DA RPZ 4DA
0.004 0.004 0.004 0.006
Mounting adapters with fixing lugs for
RPM 1ppp RPM 2ppp RPM 3ppp RPM 4ppp
20 20 20 20
RPZ 1FA RXZ E2FA RPZ 3FA RPZ 4FA
0.002 0.002 0.003 0.004
Clip-in legends (sheet of 108 legends)
All relays
10
RXZ L520
0.080
Metal maintaining clamp (for single-pole relays) Mounting adapters for 5 rail (2)
7
Socket type
106046
RPZ 1DA
8 RPZ 3FA
(1) See timer module description (selection of functions and time delays) on page 39. (2) Test button becomes inaccessible.
Presentation : page 40
Characteristics : page 41
9 10
44
References : page 43
Dimensions : page 45
Schemes : page 47
Weight kg 0.001
Zelio Relay - plug-in relays
Dimensions
RPM power relays
Dimensions Power relays
1
RPM 1
3
27
6,5 6 5
3,5
4,7
6 7
Common side view
RPM2
RPM 3
RPM 4
4,6 4,6 4,6
4,6 4,6
27
27
3
7,1 6 4,6 4
7
4,6
39
8
4,6 4,6 4,6 4,6
21
31
10
27
40
2
2,6
2,6
14
10
10
41
10
10
10
4
14,2
Sockets
8
5
12
42 4
12 1
(1)
5 6
4
80
(2)
14
40
40
44
5
4
80
(2) A1
14
13
A2 14
A1 13
11
41
11
9
12
9
17
8
21
71
19
4
4
31
A2
40
30
80 RPZ F3
30
RPZ F4
Ø4,5 x 6
Ø4,5 x 6 24 6 42
14
22
4
2
8 12
1
34 7
4
24 6
42 4
68
(1)
68
44
5
40
44 8
32 3
14
8
5 22
2
12 1
40
19
80
7
26
76
Common side view
Ø4,5 x 6
4
(3)
14
1
(1)
Ø4,5 x 6
19
40
RPZ F2
19
68
RPZ F1
9
14
30 76
4
8
10
21
A2 13 41
11
12
9
28
A1
14
13 41
12
A1
Ø4,5 x 6
40
A2
40
(2)
11
31
21
10
36
37
46
40
50
11 9
Ø4,5 x 6
10
(1) Relays (2) Protection module (3) Maintaining clamp
45
Zelio Relay - plug-in relays
Dimensions (continued)
RPM power relays
Dimensions (continued)
Mounting adapters for 5 rail
50
50
RPZ 4DA
24
20
34
44
2,5
23
Mounting adapters with fixing lugs for
3,5 16
3,5
4
19
24
3,5 19
4
16
38
43
38
38
5 16,5
RPZ 4FA
43
RPZ 3FA
43
43
4
RXZ E2FA
38
RPZ 1FA
5
4
24
2,5
3
3
23 23
RPZ 3DA
2,5
49,5
2
RXZ E2DA
38
RPZ 1DA
48
1
3,5
4
34
44
Mounting Mounting adapters for 5 rail (1)
Mounting adapters with fixing lugs for
6 7 (1) Test button becomes inaccessible
8 9 10 Presentation : page 40
46
Characteristics : page 41
References : page 43
Dimensions : page 45
Schemes : page 47
Zelio Relay - plug-in relays
Schemes
RPM power relays
Schemes
Power relays
1 A2 A1
44
42
41
34
32
31
24
22
21
14
12
A2 A1
11
44
42
RPM 4ppp
41
24
22
21
14
12
A2 A1
11
24
22
RPM 3ppp
21
14
12
A2 A1
RPM 2ppp
11
14
12
11
RPM 1ppp
2 1
1
4
1
2
4
1
2
3
4
12
12
22
12
22
42
12
22
32
42
5
5
8
5
6
8
5
6
7
8
14 9
14 9
24 12
14 9
24 10
44 12
14 9
24 10
34 11
44 12
21
41 14 ( )
11 13 (+)
21
31
41 14 ( )
A2
A1
13 (+)
14 ( )
11 13 (+)
21 14 ( )
11 13 (+)
A1
A2
A1
A2
A1
11
3
A2
Symbols shown in blue correspond to Nema marking.
Sockets RPZ F1
RPZ F2
RPZ F3
4
RPZ F4
5 14
8 44
5 14
8 44
6 24
5 14
8 44
7 34
6 24
5 14
1 12
4 42
1 12
4 42
2 22
1 12
4 42
3 32
2 22
1 12
5 14 13 A2 A1 INPUT 9 11
14 A2 12 41
13 A1 9 11
14 A2 12 41
10 21
13 A1
9 11
14 A2 12 41
11 31
10 21
13 A1 9 11
6
Symbols shown in blue correspond to Nema marking.
Protection modules RXM 040W, RUW 240BD
RXM 041ppp, RUW 241P7
RXM 021ppp, RUW 242pp
– A2
– A2
– A2
+ A1
+ A1
+ A1
7 8 9 10
47
Technical presentation
Zelio Relay - plug-in relays
Relays
types
1
Symbol
2 3
Configuration Make (Normally Open)
EU NO
USA SPST-NO DPST-NO nPST-NO (1)
Break (Normally Closed)
NC
SPST-NC DPST-NC nPST-NC (1)
Changeover
CO
SPDT DPDT nPDT (1)
Utilisation categories
4 5 6
Category AC-1
Type of current a single-phase a 3-phase
Applications Resistive or slightly inductive loads.
AC-3
a 3-phase
Starting and braking of squirrel cage motors; reversing direction of rotation only after stopping of motor.
AC-4
a 3-phase
Starting of squirrel cage motors, inching. Plugging, reversing direction of rotation.
DC-1
c
Resistive or slightly inductive loads (2).
AC-14
a single-phase
Control of electromagnetic loads (< 72 VA), auxiliary control relays, power ors, electromagnetic solenoid valves and electromagnets.
AC-15
a single-phase
Control of electromagnetic loads (> 72 VA), auxiliary control relays, power ors, electromagnetic solenoid valves and electromagnets.
DC-13
c
Control of electromagnetic loads, auxiliary control relays, power ors, magnetic solenoid valves and electromagnets.
Protection categories
7 8
Category RT 0
Explanation Condition Unenclosed relay Relay not provided with a protective case.
RT I
Dust protected relay
Relay provided with a case which protects its mechanism from dust.
RT II
Flux-proof relay
RT III
Wash-tight relay
Relay capable of being automatically soldered without allowing the migration of solder fluxes beyond the intended areas. Relay capable of being automatically soldered and then washed to remove flux residues without risk of ingress of flux or washing solvents.
RT IV
Sealed relay
RT V
Relay provided with a case which has no venting to the outside atmosphere.
Hermetically Sealed relay having an enhanced level of sealing. sealed relay (1) n = number of s. (2) The switchable voltage can be doubled, for an equal current, by connecting two s in series.
9 10
48
Zelio Relay - plug-in relays
Presentation
Protection modules
Whenever an inductive load is de-energised (coil of a relay or of a or), an overvoltage appears at its terminals. This voltage peak can reach several thousand volts and a frequency of several MHz. It is likely to disturb the operation of automation systems which contain electronic devices. Protection modules are used to reduce the voltage peak on de-energisation and they therefore limit the energy of interference signals to a level that will not disturb surrounding coils and electronic devices. These modules are used to avoid: v electromagnetic compatibility problems, v the deterioration of materials, v the destruction of insulation due to overvoltage, v the destruction of electronic components.
U Supply voltage
Energy released
b v v v
t
Coil voltage with diode protection module (c only)
U
Disadvantages increase in relay drop-out time (3 to 4 times the usual time), no polarity protection, de-energisation of the relay.
4
Protection module with varistor b Advantages v can be used with a and c supply, v voltage peak limited to about 2 Un, v little effect on relay drop-out time.
Break
5
b Disadvantages v no modification of coil’s own oscillating frequency, v limitation of switching frequency.
Limitation of voltage peaks
t
Energy released
6 7
Coil voltage with varistor protection module (a and c)
U
Protection module with RC circuit b Advantages v coil oscillating frequency reduced to about 150 Hz, v voltage peak limited to 3 Un, v little effect on relay drop-out time.
Break
t
8
b Disadvantages v no protection for low voltages.
U2
U1
S2 (with RC)
2 3
Diode protection module (with or without LED) b Advantages v accumulation of energy allowing current flow in the same direction, v absence of any voltage peaks at the coil terminals, v low cost.
Break
1
S1
9
Coil voltage with RC circuit protection module (a only) S1 = S2 = Energy released
10
49
Selection guide
Interfaces
Interfaces for discrete signals
Applications
Electromechanical interface modules
Functions
Input
Width (mm)
17.5
9.5
arrangement
1 N/O 2 N/O 1 C/O
1 N/O
Thermal current
–
Control voltages
c 110…127 V z 24 V, 48 V a 115…127 V a 230/240 V
c 24 V, 48 V a 115…127/50 Hz a 115…127/60 Hz a 230…240/50-60 Hz
Indication
Mechanical for s and/or LED for control
LED for control
References
ABR 1E
ABR 2E
Pages
56
62
1 2 3 4 5 6 7 8 9 10
50
Solid state interface modules
1 2 3 4 Output
Input and output Very low level switching
Input
Output
9.5/17.5
17.5
12
17.5
9.5
1 N/O 2 N/O 1 C/O 1 N/C + 1 N/O
1 N/O
1 C/O
–
12 A
5A
–
c 24 V z 24 V, 48 V a 115…127 V a 110 V
c 24 V
Mechanical for s and/or LED for control
LED for control
ABR 1S
ABR 2S
ABR 2pB312B
ABS 2E
56
62
62
68
5 5A
c 5, 24, 48 V a 115…127/50 Hz a 120…127/60 Hz a 230…240/50 Hz a 230…240/60 Hz
6
c 24 V
7 ABS 2S
8 9 10
51
Interfaces
Presentation
For discrete signals
Electromechanical interface modules
ABR-1 electromechanical interface modules are supplied in the form of compact modules, 17.5 mm wide. They are designed for interfacing discrete digital control signals exchanged within an automated system between the processing unit (PLC, numerical controller, etc) and the other components (ors, solenoid valves, indicator lamps, proximity sensors, etc). These products are based on or technology and are notable for their excellent adaptation to industrial environments, ensured by the fact that they conform to the most recent IEC 947-5-1 standards.
1
Composition
816264
2
The ABR-1 range comprises 2 families : 5
Input interfaces Input interfaces are designed for switching input signals to the processor and are characterized by their high degree of reliability : less than 1 fault per 100 million operating cycles at c 17 V, 5 mA. The switching level is sufficiently high to ensure that the interfaces can directly control most ors and indicator lamps.
2 1
3
4
4
816265
3
Output interfaces Output interfaces are designed for the control of preactuators (ors, solenoid valves, etc) for signalling devices (indicators lamps, audible warnings, etc). They are characterized by a high switching capacity and an average durability 5 times greater than that of traditional interface modules which incorporate standard relays.
5
1 Override s by pressing button (not holding it down) for a simple and quick test during setting up or maintenance operations on the installation 2 Green indicator showing the mechanical position of the s 3 LED indicating the control signal state 4 Channel identification : 5 individual characters for AB1-R/G or one AB1-SA2 marker tag 5 Connection by screw clamp terminal enabling easy attachment of 2 wires per terminal. The layout of the connection terminals for both families (input and output) is designed for rational wiring and a clear separation between the incoming (processing) and outgoing (power and process control) circuits.
3
5
4 1 2
6 7 8 9 10 Presentation: page 52
52
Characteristics: page 53
Curves: page 55
Dimensions, schemes: page 57
Interfaces
Characteristics
For discrete signals
Electromechanical interface modules
Examples of applications with PLCs PLC Positive logic discrete inputs
–/
+/
1
PLC Positive logic transistor (or relay) outputs
+/
–
A2
A1
A2
A1
A2
3
+ 24...125 V
+
2
A1
A2
A1
A2
A1
A2
A1
A2
A1
–/
...240 V
(1) Pushbuttons Series s
2-wire sensors
3-wire sensors
Pushbuttons Series s
(1) Essential on inductive loads (can be replaced with peak limiter
(1)
–
2-wire sensors
4
).
Environment Conforming to standards Product certifications Degree of protection Protective treatment Flame resistance
Conforming to IEC 529 (protection against direct ) Conforming to IEC 695-2-1
Shock resistance Vibration resistance Resistance to electrostatic charges Resistance to rapid transients
Conforming to IEC 68-2-27 Conforming to IEC 68-2-6 Conforming to IEC 801-2
Resistance to shock waves
Conforming to IEC 255-4
Cross-sections which may be connected
Flexible cable with no cable end Flexible cable with cable end Rigid cable
Operating position Ambient air temperature around the device Operating altitude Installation category Degree of pollution Mounting
IEC 947-5-1 UL, CSA, BV, LROS, DNV IP 00
Conforming to IEC 801-4
Unrestricted operation Permissible at Un Storage Conforming to IEC 947-1 Conforming to IEC 947-5-1
Incandescent wire Conforming to UL 94 Semi-sinusoidal waves 11 ms 10…55 Hz Level 3
°C
On power supply On I/O Waveform 1.2/50 ms ; 0.5 J
kV kV kV kV mm2 mm2 mm2 mm2
1 or 2-wire 1 or 2-wire 1-wire 2-wire
U ≤ 50 V U > 50 V
kV
°C °C °C m
5
“TC” 850 V0 50 gn 6 gn 8
6
2 1 0.5 2.5 0.6…2.5 0.34…2.5 0.27…4 0.27…2.5 Any - 5…+ 40 - 20…+ 60 - 40…+ 70
7 8
≤ 3000 II 3 Standard rails 5 1 4
9 10
53
Interfaces
Characteristics (continued)
For discrete signals
Electromechanical interface modules
Control circuit characteristics (40°C ambient temperature)
1 2 3
Type of interface Rated voltage (Uc)
V
ABR 1Sp02B c 24
Current frequency Energization threshold (at ± 5 %) Maximum operating voltage Maximum drop-out (at ± 5 %) voltage (Uo) Maximum current (Un) Minimum holding current Maximum dissipated power Disappearance of voltage maximum time up to which is maintained Display of control circuit by LED Built-in protection reversed polarity
Hz V V V mA mA W ms
– 15 30 3.2 62 6.6 1.5 3
50/60 16.5 30 3.8 62/55 4.9/5.2 1.5 8
50/60 34 53 8.5 36/32 4.7/5.4 1.5 10
ABR 1Ep12F c 110...127 – 75 140 16 15 1.5 1.5 10
No Yes
Yes Yes
Yes Yes
Yes Yes
5 6
Type of interface Maximum switching voltage
9
Conforming to IEC 947-5-1
Operating current frequency Thermal current Ith Conforming to IEC 947-1 Rated operating Conforming to IEC 947-5-1 current (Ie) Ue : a 230 V per 1 million operating cycles Conforming to IEC 947-5-1 Ue : c 24 V
AC12 AC13 AC14 AC15 DC12 DC13
Minimum switching capacity Minimum switching voltage Protection against For Ik ≤ 2.5 kA (a) and ≤ 100 A (c) short-circuits Type and value of recommended fuse Low power switching Number of faults reliability of s per “n” million operating cycles (17 V - 5 mA)
aV cV aV cV Hz A A A A A A A mA V A
ABR 1ppp1F a 115...127 50/60 86 140 34 8 2.4 1.5 6
ABR 1Ep11M a 230...240 50/60 170 264 68 7 2 1.5 5
ABR 1Ep01M a 230...240 50/60 164 264 78 5.5 1.5 1.5 6
Yes –
Yes –
No –
ABR 1Epppp 252 125 230 125 50/60 2 2 1 1 1 2 1 3 17 gG/gF : 16
ABR 1Spppp 252 125 230 125 50/60 12 4 1 1 1 5 1 3 17 gG/gF : 16
10-8
10-8
Other characteristics
Operating time at Un and at 20 °C
7 8
ABR 1ppp8E z 48
characteristics
Maximum rated operating voltage Ue
4
c/a c/a c/a c/a 50 Hz/60 Hz
ABR 1ppp8B z 24
Duration of bounce bridging times between “N/C” and “N/O” Maximum operating rate
Between energization of coil and closing of N/O Between energization of coil and opening of N/C Between de-energization of coil and opening of N/O Between de-energization of coil and closing of N/C Maximum make before break or break before make time At no-load At Ie ABR-1 (1 N/O or 2 N/O) ABR-1 (1 C/O or 1 N/C + 1 N/O)
Mechanical durability in millions of operating cycles Rated isolation voltage Conforming to IEC 947-1 Conforming to VDE 0110 group C Insulation test voltage Between coil circuit and circuits for 1 min. Between wired interface and earth Between independent s
ms
≤ 12
ms
≤ 12
ms
≤ 12
ms
≤ 12
ms ms
≤3 1
Hz Hz
6 0.5 ≥ 20 million ≥ 10 million
V V kV kV kV
250 250 4 2.5 1.5
10 Presentation: page 52
54
Characteristics: page 53
Curves: page 55
Dimensions, schemes: page 57
Interfaces
Curves
For discrete signals
Electromechanical interface modules
Electrical durability of s
Test conditions : in accordance with standard IEC 947-5-1 set up for rated control voltage, operating rate : 1800 cycles/hour. (0.5 Hz).
1
a.c. loads Operating cycles in millions
Operating cycles in millions
6
6
5
5
4
4
2
3 2
2 1
3 2
3 4
1
1
3
2 3 4
0
0 0
1
2
3
4
5
0
6 (A)
AC-12 : control of resistive loads and isolated solid state loads via optocoupler cos j ≥ 0.9
1
2
3
4
5
6 (A)
AC-13 : control of isolated solid state loads via transformer cos j ≥ 0.65
4
Operating cycles in millions 3
AC-14 : control of weak electromagnetic loads of electromagnets ≤ 72 VA make: cos j = 0.3 break: cos j = 0.3 AC-15 : control of electromagnetic loads of electromagnets > 72 VA make: cos j = 0.7 break: cos j = 0.4
1
2
2 3
5 6
4
1
1 2 3 4
0 0
0,5
1
1,5
2
2,5
24 V 48 V 127 V 230 V
3 (A)
7
d.c. loads Operating cycles in millions
Operating cycles in millions
6
3
1 24 V 2 48 V 3 127 V
5
8
1 4
2
3 2 1
1
1
2
0
3
0 0
1
2
9
2
3 3
4
5
6
0
0,5
1
1,5
2
2,5
(A)
DC-12 : control of resistive loads and isolated solid state loads via optocoupler L/R ≤ 1 ms
3 (A)
DC-13 : control of electromagnets L/R ≤ 2 x (Ue x Ie) in ms. Ue: rated operating voltage Ie: rated operating current
10
55
Interfaces
References
For discrete signals
Electromechanical interface modules Control circuit : a.c. or d.c.
816264
Input interface modules (1) (17.5 mm pitch) Display
1
Mechanical (2) Mechanical (2) + LED (3)
Composition
1 N/O 1 C/O 1 N/O
2 2 N/O
3
818215
ABR 1E101M
1 C/O
V a 230/240 a 230/240 z 24 z 48 c 110...127 (4) a 115...127 a 230/240 z 24 z 48 c 110...127(4) a 115...127 a 230/240 z 24 z 48 c 110...127(4) a 115...127 a 230/240
Enclosure Reference colour Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey
Output terminals-relays (1) (17.5 mm pitch)
4
Display
Mechanical (2)
ABR 1E318B Mechanical (2) + LED (3)
816265
5
Control circuit
Composition
1 N/O 2 N/O 1 C/O 1 N/C + 1 N/O 1 N/O
2 N/O
1 C/O
6
1 N/C + 1 N/O
7
Commoning links
ABR 1S102B
816273
Description
For common
Commoning Coil links in modules 2 8 x 1 mm a
8
c
Control circuit V c 24 c 24 c 24 c 24 z 24 z 48 a 115...127 z 24 z 48 a 110 z 24 z 48 a 110 z 24 z 48 a 110 Colour
White Red Blue
Enclosure Reference colour Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey Grey
Distance between cable ends cm 12 2 12 2 12 2
9 10
56
ABR 1S102B ABR 1S402B ABR 1S302B ABR 1S602B ABR 1S118B ABR 1S118E ABR 1S111F ABR 1S418B ABR 1S418E ABR 1S411F ABR 1S318B ABR 1S318E ABR 1S311F ABR 1S618B ABR 1S618E ABR 1S611F Reference
ABF C08R12W ABF C08R02W ABF C08R12R ABF C08R02R ABF C08R12B ABF C08R02B
kg 0.090 0.090 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 Weight kg 0.090 0.090 0.090 0.090 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 Weight kg 0.020 0.010 0.020 0.010 0.020 0.010
(1) Connection by screw-clamp. (2) By green mechanical indicator light for (s) activated electrically or mechanically by pressing the test button. (3) By green LED illuminated when control signal is present. (4) With polarization (+ on A1, - on A2).
ABF C08Rppp
Presentation: page 52
ABR 1E101M ABR 1E301M ABR 1E118B ABR 1E118E ABR 1E112F ABR 1E111F ABR 1E111M ABR 1E418B ABR 1E418E ABR 1E412F ABR 1E411F ABR 1E411M ABR 1E318B ABR 1E318E ABR 1E312F ABR 1E311F ABR 1E311M
Weight
Characteristics: page 53
Curves: page 55
Dimensions, schemes: page 57
Interfaces
Dimensions, schemes
For discrete signals
Electromechanical interface modules
Dimensions
ABR 1S
78
74
1
74
ABR 1E
78
17,5
70,5
2
17,5
70,5
75
75
63
63
3
Schemes
c 24 V or a 230 V interfaces with mechanical indication A1
A1
A2
1 N/C + 1 N/O
A2
A2
2 N/O A1
1 C/O A1
A2
1 N/O
4 14
13
14
14
11
12
13
24
23
24
23
12
11
5
z 24 V or z 48 V interfaces with mechanical indication + LED
6
A1
A2
A2
1 N/C + 1 N/O A1
2 N/O A1
A2
1 C/O A1
A2
1 N/O
7 14
14
13
11
12
14
13
24
23
24
23
12
11
8
c / a 110 V or a 230 V interfaces with mechanical indication + LED
A2
A1 (+)
1 N/C + 1 N/O A1 (+)
A2
A2
2 N/O A1 (+)
1 C/O A1 (+)
A2
1 N/O
9 14
13
14 12
11
14
13
24
23
24
23
12
11
10
57
Interfaces
Presentation
For discrete signals
Slim electromechanical interface modules
ABR-2 electromechanical interface modules complement the ABR-1 range. They are characterised by micro relay technology which allows reduced dimensions and very low switching levels (TTL, HCMOS, analogue signals). The ABR-2 family is in the form of slim compact modules, 9.5 mm wide for input interface modules, 12 mm wide for output interface modules and 17.5 mm wide for very low level switching products.
1
Description
3
2
2
3
The ABR-2 comprises 3 families : Input interfaces (9.5 mm pitch) Input interfaces are designed for switching input signals to a processor and are characterized by their high degree of reliability : less than 1 fault per 100 million operating cycles at c 17 V, 5 mA. An assured immunity to current leakages ≤ 2 mA, and a wide coil voltage range (0.7 to 1.25 Un).
1
3
4
1 2
5 3
6
Output interfaces (12 mm pitch) Output interfaces are designed for the control of preactuators (ors, solenoid valves, etc) for signalling devices (indicators lamps, audible warnings etc). They are characterized by a high switching capacity and an assured immunity to current leakages £ ���������������������������������������������������������������� 2 mA. A lower cost version without LED signalling is available. Low level switching input and output interfaces (17.5 mm pitch) with 1 C/O . These interfaces are designed for switching logic (TTL or HCMOS) and analogue signals. Warning : never switch inductive loads with this type of interface. The front of the ABR-2 electromechanical interface module comprises : 1 LED indicating the control signal state 2 Channel identification : 5 individual characters for AB1-R/G or 1 AB1-SA2 marker tag 3 Connection by screw clamp terminal enabling easy attachment of 2 wires per terminal. The layout of the connection terminals for both families (input and output) is designed for rational wiring and a clear separation between the incoming (processing) and outgoing (power and process control) circuits.
1 2
7 ABR-2SB312B
8
ABR2SB312B-PRO-3-B
9 10 Presentation: page 58
58
Characteristics: page 59
Curves: page 61
References: page 62
Dimensions, schemes: page 63
Interfaces
Characteristics
For discrete signals
Slim electromechanical interface modules
Examples of applications with PLCs PLC Positive logic discrete inputs
–/
PLC Positive logic transistor (or relay) outputs
+
Processing power supply +/
PLC Analogue inputs
Channel X
A2
2 3
11
A1 14
12
A2 14
A1 13
A2 14
A1
14 A2
13
13 A1
A2
14 A2
14
13 A1
A1
14 A2
OV
13
13 A1
–
+ Process power supply
+/
1
C1
(1)
(1) Pushbuttons Series s
2-wire sensors
3-wire sensors
ABR 2Epppp
– ABR 2Spppp
(1) Essential on inductive loads (can be replaced with peak limiter
C2 Analogue sensors
4
ABR 2SB12B
).
Environment Conforming to standards Product certifications Degree of protection Protective treatment Flame resistance
Conforming to IEC 529 (protection against direct ) °C
kV
“TC” 960 V0 30 gn 3 gn 8
Shock resistance Vibration resistance Resistance to electrostatic discharges Resistance to electromagnetic fields Resistance to rapid transients
Conforming to IEC 68-2-27 Conforming to IEC 68-2-6 Conforming to IEC 801-2
Incandescent wire Conforming to UL 94 Semi-sinusoidal waves 11 ms 10…150 Hz Level 3
Conforming to IEC 801-3
Level 3 ; 27…1000 MHz
V/m
10
Conforming to IEC 801-4 Level 3
Resistance to shock waves
Conforming to IEC 947-1
On power supply On I/O Waveform 1.2/50 ms ; 0.5 J
Cross-sections which may be connected
Flexible cable with no cable end Flexible cable with cable end Rigid cable
kV kV kV kV kV mm2 mm2 mm2 °C °C
2 1 0.5 1.5 2.5 0.6…2.5 0.34…2.5 0.27…4 Any - 5…+ 40 - 5…+ 55
°C
- 25…+ 70 (2)
°C m
- 40…+ 80 ≤ 3000 II 2 Standard rails 5 1 4
Operating position Ambient air temperature
Conforming to IEC 695-2-1
5
IEC 947-5-1 UL, CSA, BV, LROS, DNV IP 20
1 or 2-wire 1 or 2-wire 1-wire
Unrestricted operation Operation from 0.85...1.1 Us (assigned voltage) Operation restricted to Us (assigned voltage) Storage
Operating altitude Installation category Conforming to IEC 947-1 Degree of pollution Conforming to IEC 947-1 Mounting (2) Leave space of 8 mm between ABR-2S1ppp for an ambient temperature ≥ 55 °C
U < 50 V U < 150 V U < 300 V
6 7 8 9 10
59
Interfaces
Characteristics (continued)
For discrete signals
Slim electromechanical interface modules
Control circuit characteristics (40°C ambient temperature)
1 2 3 4 5
Type of interface Rated voltage (Us)
V
Current frequency Energization threshold Maximum operating voltage Maximum drop-out voltage (Uo) Maximum current (at Us) Minimum holding current Maximum dissipated power (at Us)
Hz V V V mA mA W W ms
50 Hz 60 Hz
Disappearance of voltage maximum time up to which is maintained Display of control circuit by LED Built-in protection reversed polarity
ABR ABR ABR 2E112B 2E112E 2E115F c 24 c 48 z 115…127 – – 50 16.9 37.3 93 28.8 57.6 140 3.8 8.5 25.4 19.5 11 14 2 2 2.5 – – 0.66 0.45 0.52 – 1 1 10
ABR 2E116F z 120...127 60 97 140 25.4 16 2.5 – 0.73 10
ABR 2E111M a 230...240 50/60 186 264 48 15 2.5 0.54 0.77 10
ABR ABR ABR 2S112B 2S102B 2pB312B (1) c 24 c 24 c 24 – 16.9 28.8 3.8 28 2 – 0.64 1
– 14.5 28.8 2 18 1.3 – 0.43 5
– 16.9 28.8 3.8 23 2 – 0.55 1
Yes Yes
Yes –
Yes –
Yes Yes
No Yes
Yes Yes
Yes Yes
Yes –
characteristics (40°C ambient temperature)
Type of interface Composition Maximum rated Conforming to IEC 947-5-1 operating voltage (Ue max) Maximum switching voltage Operating current frequency Thermal current Ith Conforming to IEC 947-1 Rated operating Conforming to IEC 947-5-1 current (Ie) Ue max for 1 million operating cycles Conforming to IEC 947-5-1 Ue : c 24 V
aV cV
AC12 AC14 AC15 DC12 DC13
Minimum switching current Minimum switching voltage Protection against For Ik ≤ 1 kA (a) and ≤ 100 A (c) short-circuits Type and value of recommended fuse
6
Low level Number of faults reliability (17 V, 5 mA)/ per “n” million operating cycles ABR-2pB (30 mV, 10 µA)
7
Maximum operating Between energization of coil c time and closing of N/O a at Us (bounce included) Between energization of coil and opening of N/C Between de-energization of coil c and opening of N/O a
aV cV Hz A A A A A A mA V
ABR 2Epppp 1 N/O 127 100
ABR 2S112B 1 N/O 230 120
ABR 2S102B 1 N/O 230 120
ABR 2pB312B (1) 1 C/O 48 48
140 250 250 125 150 150 50/60 50/60 50/60 1 5 5 1 3 3 0.5 1 1 0.5 1 1 1 1.7 1.7 1 1.5 1.5 1 5 5 5 5 5 Type : quick-blow fuse with high breaking capacity 2 6.3 6.3 1 per 100 million
60 60 50/60 0.05 – – – – – 0.01 0.01
ms ms ms
10 30 –
10 – –
10 – –
6 – 6
ms ms ms
6 30 –
12 – –
5 – –
6 – 6
ms ms ms
5 – –
5 – –
5 – –
2 5 2
Hz Hz
10 0.5 20
10 0.5 10
10 0.5 10
10 – 20
V V kV rms kV rms kV rms
300 250 2 2.5 0.75
300 250 4 2.5 1
300 250 4 2.5 1
300 250 1.5 2.5 1
A
0.4
Other characteristics
8 9
Between de-energization of coil and closing of N/C Maximum duration of bounce No make before break Maximum make On energization guaranteed between before break or break On de-energization “N/C” and “N/O” s before make time Maximum operating At no-load rate At Ie Mechanical durability in millions of operating cycles Rated insulation Conforming to IEC 947-1 voltage Conforming to VDE 0110 group C Insulation test voltage Coil circuit/ circuits for 1 min Wired interface/earth Between open s (1) Do not switch inductive loads.
10 Presentation: page 58
60
Characteristics: page 59
Curves: page 61
References: page 62
Dimensions, schemes: page 63
Interfaces
Curves
For discrete signals
Slim electromechanical interface modules
Electrical durability of s (ABR 2S) Test conditions : in accordance with standard IEC 947-5-1 set up for rated control voltage.
1
a.c. loads Operating cycles in millions
Operating cycles in millions
6
3
1 2 3 4
5
24 V 48 V 115 V 230 V
2
2
4
1
3
2 1
2 1
4
0 0
1
2
3
3
1 2 3 4
3
0
4
5
0
6 (A)
AC12 : control of resistive loads and isolated solid state loads via optocoupler cos j ≥ 0.9
0,5
1
1,5
2
2,5
3 (A)
4
AC14 : control of weak electro-magnetic loads of electro-magnets y 72 VA make : cos j = 0.3 break : cos j = 0.3 AC15 : control of electro-magnetic loads of electro-magnets > 72 VA make : cos j = 0.7 break : cos j = 0.4
5
d.c. loads Operating cycles in millions
Operating cycles in millions
3
3
2
1 24 V 2 48 V 3 115 V
6
2
1
1 1
3
7
2
3
1
2
0
0 0
0,5
1
1,5
2
2,5
3
0
0,5
1
1,5
2
2,5
DC12 : control of resistive loads and isolated solid state loads via optocoupler L/R ≤ 1 ms
3
8
(A)
(A )
DC13 : control of electro-magnets L/R ≤ 2 x (Ue x Ie) in ms. Ue : rated operating voltage Ie : rated operating current (with a load protection diode)
9 10
61
Interfaces
References
For discrete signals
Slim electromechanical interface modules Control circuit : a.c. or d.c.
816362
Input modules (9.5 mm pitch) Indication
1
With LED
Composition
Control circuit
1 N/C
V c 24
5
ABR 2E112B
kg 0.032
c 48
5
ABR 2E112E
0.032
a 115...127 (50 Hz)
5
ABR 2E115F
0.035
a 120...127 (60 Hz)
5
ABR 2E116F
0.035
a 230...240 (50/60 Hz) 5
ABR 2E111M
0.036
2 ABR 2E112B
Indication
Composition
Control circuit
Sold in Unit lots of reference
Weight
Without
1 N/C
V c 24
5
ABR 2S102B
kg 0.040
With LED
1 N/C
c 24
5
ABR 2S112B
0.041
Modules for very low level switching (17.5 mm pitch)
4
Indication
Composition
Control circuit V
Reference
Weight kg
1 C/O (1)
c 24
ABR 2EB312B
0.048
1 C/O (1)
c 24
ABR 2EB312B
0.048
Input With LED
Output
ABR 2S112B
With LED
Flexible comb accessories
816364
5
Weight
Output modules (12 mm pitch)
816363
3
Sold in Unit lots of reference
Description For common
Flexible comb modularity 8 x 1 mm2
6
Coil
a
7
c
ABR 2EB112B
Colour
White
Red
Blue
Distance between cable ends cm 12
Reference
Weight
ABF C08R12W
kg 0.020
2
ABF C08R02W
0.010
12
ABF C08R12R
0.020
2
ABF C08R02R
0.010
12
ABF C08R12B
0.020
2
ABF C08R02B
0.010
816365
(1) Do not switch inductive loads.
8 ABF C08Rppp
9 10 Presentation: page 58
62
Characteristics: page 59
Curves: page 61
References: page 62
Dimensions, schemes: page 63
Interfaces
Dimensions, schemes
For discrete signals
Slim electromechanical interface modules
Dimensions
ABR 2S1p2B
1
78
74
74
ABR 2E11pp
78
9,5
70,5
75
75
ABR 2SB312B
78
78
17,5
70,5
75
75
63
63
ABR 2E112B (c 24 V)
4
17,5
70,5
Circuit diagrams
13
74
3
74
ABR 2EB312B
2
12
70,5
ABR 2E112E (c 48 V)
5
ABR 2E11pF/M (a 115...240 V)
14
13
14
14
13
A2
–
A1
7
+A1
ABR 2pB312B (c 24 V)
–A2
–A2
+A1
ABR 2S112B (c 24 V)
–A2
+A1
–A2
ABR 2S102B (c 24 V)
+A1
–A2
+A1
6
8 14
13
14
13
11
12 14
9 10
63
Interfaces
Presentation
For discrete signals
Slim solid-state interface modules
The ABS-2 solid-state interface relays are supplied in the form of compact modules which appear identical to the ABR-2 electromechanical family. They are designed for interfacing discrete digital control signals exchanged within an automated system between the processor (PLC, numerical controller, etc) and the other components (ors, solenoid valves, indicator lamps, proximity sensors, etc). They are suitable for use in equipment which requires the benefits of electronic technology : a high operating rate, virtually unlimited durability, silent operation, etc. These products are notable for their high performance and excellent adaptation to industrial environments, ensured by the fact that they conform to the most recent IEC standards.
1 2 816380
Composition
3
Input interfaces The 9.5 mm wide input interfaces are designed for switching input signals to processors. They offer a wide choice of electrical isolation between signals due to the wide range of input voltages from c 5 V to a 230 V.
3 2 1
816378
4 3
5
1 2
816379
6 7
The ABS-2 range comprises 2 families :
Output interfaces Output interfaces are designed for the control of preactuators (ors, solenoid valves, etc) for the signalling devices (indicator lamps, audible warnings, etc). Two widths are available, 9.5 and 17.5 mm, depending on the switched current. The 17.5 mm version comprises a 9.5 mm interface and an integrated 8 mm spacer. This device can, with its increased ventilation, switch high levels of currents. The front of the ABS-2 slim solid-state interface modules comprises: 1 LED indicating the state of the control signal. 2 Channel identification : 5 individual characters for AB1-/G or one AB1-SA2 marker tag. 3 Connection by screw clamp terminal enabling easy attachment of 2 wires per terminal. The layout of the connection terminals for both families (input and output) is designed for rational wiring and a clear separation between the incoming (processing) and outgoing (power and process control) circuits. 4 Integrated spacer.
3 ABS2INTERSORT-PRO-3-B 1 2 4
8 9
ABS-2
ABS2-PRO-3-B
10 Presentation: page 64
64
Characteristics: page 65
Curves: page 68
References: page 68
Dimensions, schemes: page 69
Interfaces
Characteristics
For discrete signals
Slim solid-state interface modules
Examples of applications with PLCs Interfacing PLC discrete inputs PLC Positive logic discrete inputs
+
Processing power supply
13
13
13
13
A2
A1
A2
A1
A1
– PNP
Pushbuttons Series s
2-wire 3-wire sensors sensors
14
13
14
3
F
+
Process power supply
13
13
A1
A2
A1
A2
A1
A2
A1
ABS - 2S
A2
A1
A2
2
13
ABS - 2E
+
A2
–
14
14
14
14
14
+
1
PLC Positive logic transistor (or relay) outputs
14
–
Interfacing PLC discrete outputs
115/ 230 V Pushbuttons Series s
4
–
2-wire sensors
Environment Conforming to standards Product certifications Degree of protection Protective treatment Flame resistance
Conforming to IEC 529 (protection against direct ) °C
kV
“TC” 960 V0 30 gn 5 gn 8
Shock resistance Vibration resistance Resistance to electrostatic discharges Resistance to electromagnetic fields Resistance to rapid transients
Conforming to IEC 68-2-27 Conforming to IEC 68-2-6 Conforming to IEC 801-2
Incandescent wire Conforming to UL 94 Semi-sinusoidal waves 11 ms 10…150 Hz Level 3
Conforming to IEC 801-3
Level 3 ; 27…1000 MHz
V/m
10
Conforming to IEC 801-4 Level 3
Resistance to shock waves
Conforming to IEC 947-1
On power supply On I/O Waveform 1.2/50 ms ; 0.5 J
Cross-sections which may be connected
Flexible cable with no cable end Flexible cable with cable end Rigid cable
kV kV kV kV kV mm2 mm2 mm2
2 1 0.5 1.5 2.5 0.6…2.5 0.34…2.5 0.27…4 Any - 5…+ 55 - 25…+ 70 - 40…+ 80 ≤ 300 II 2 Standard rails 5 1 4
Operating position Ambient air temperature around the device Operating altitude Installation category Degree of pollution Mounting
Conforming to IEC 695-2-1
Unrestricted operation Operation at Us Storage Conforming to IEC 947-1 Conforming to IEC 947-1
5
IEC 947-5-1 Draft standard IEC 17 B secretariat 200 UL, CSA, BV, LROS, DNV IP 20
1 or 2-wire 1 or 2-wire 1-wire
U < 50 V U < 150 V U < 300 V
°C °C °C m
6 7 8 9 10
65
Interfaces
Characteristics (continued)
For discrete signals
Slim solid-state interface modules
Control circuit characteristics (55°C ambient temperature)
1 2
Type of interface Rated voltage Us
c a
V V
Maximum voltage
c
V
a c a c
V mA mA V mA V mA V mA V mA
Maximum current at Us State 1 assured
a
3
State 0 assured
c a
State 1 display Internal protection reversed polarity
4 5
Output circuit characteristics
Rated operating voltage Ue Min/max voltage Min/max current switched Maximum residual current at state 0 Maximum volt drop at state 1 Internal protection External protection
c c
V V mA mA V
ABS 2EC01EB 24 –
ABS 2EC01EE 48 – 57.6
ABS 2EA01EF – 115/127 50 Hz –
ABS 2EA02EF – 120/127 60 Hz –
ABS 2EA01EM – 230/240 50 Hz –
ABS 2EA02EM – 230/240 60 Hz –
Negative logic 6 (TTL) – 13.6 – 3.75 4.5 – – 2 0.09 – – Yes Yes
28.8 – 12 – 16.9 7.7 – – 5.6 2 – – Yes Yes
– 10.5 – 36 7.5 – – 10.8 2 – – Yes Yes
140 – 14 – – 86.3 8.4 – – 25.4 2.5 Yes –
140 – 17 – – 90 9.7 – – 25.4 2.5 Yes –
264 – 12.5 – – 173 7.9 – – 48 2.5 Yes –
264 – 15 – – 173 9.3 – – 48 2.5 Yes –
ABS 2EA02EF 10 20 25
ABS 2EA01EM 10 20 25
ABS 2EA02EM 10 20 25
5...48 2/60 1/50 0.1 1 Reversed polarity Against short-circuits for Ik ≤ 100 A (c) Quick-blow fuse, ref. : HA21 0.25 A or equivalent
Other characteristics Type of interface
6
ABS 2EC01EA 5 –
Time delay characteristics Response time max Ue ≤ 30 V Ie ≥ 5 mA Maximum switching rate Duty cycle 50 % Ue ≤ 30 V Ie ≥ 5 mA Rated insulation voltage Insulation test voltage for 1 minute
I/O Wired interface/earth
7
0V1 1V0
ms ms Hz
ABS 2EC01EA 0.05 0.4 1000
ABS 2EC01EB 0.05 0.4 1000
ABS 2EC01EE 0.05 0.4 1000
ABS 2EA01EF 10 20 25
kVrms kVrms
Conforming to IEC 947-1 : 300 V Conforming to VDE 0110 : 250 V group C 4 2.5
8 9 10 Presentation: page 64
66
Characteristics: page 65
Curves: page 68
References: page 68
Dimensions, schemes: page 69
Interfaces
Characteristics (continued)
For discrete signals
Slim solid-state interface modules
Control circuit characteristics (55°C ambient temperature) Type of interface Rated voltage Us Maximum voltage Maximum current at Us State 1 assured
c
State 0 assured
ABS 2SC01EB 24 28.8 12 16.9 7.7 5.6 2 Yes Yes
ABS 2SC02EB
V V A
c 5...48 c 57.6 2
A A A A mA mA V
DC12 DC13 DC14 – 1 1 1.5
V V/ms
– – Reversed polarity Against short-circuits for Ik ≤ 1 kA (a) and ≤ 100 A (c) Quick-blow fuse with high breaking capacity: 3.15 A
ms ms Hz Hz Hz Hz
0.05 0.6 DC13 DC14 – 700
kVrms kVrms
Conforming to IEC 947-1 : z 300 V Conforming to VDE 0110 : 250 V group C 4 2.5
V V mA V mA V mA
State 1 display Internal protection reversed polarity
ABS 2SA01MB 24 28.8 13.6 16.9 8.3 5.3 2 Yes Yes
ABS 2SA02MB
c 5...48 c 57.6 3
a 24...240 a 264 2.3
a 24...240 a 264 3
2.5/2.2 2.5/2.2 0.6/0.6 –
AC12 1.9/0.5 AC13 1.6/0.5 AC14 1.6/0.5 AC15 1/0.5 10 2.5 3 (Ie ≥ 10 mA) 1.5 (Ie ≥ 100 mA) 50 peak 500
2.1/1.5 1.6/1.5 1.6/1.5 1/1
1 2
Output circuit characteristics
Rated operating voltage Ue Maximum voltage Maximum continuous current (Ith) (1) at 40 °C Rated operating voltage (Ie) Conforming to IEC 947-5-1 Single/touching product at 55 °C vertical position Minimum current Maximum residual current Maximum volt drop
c/a c/a
“0 crossing” voltage Solid-state dV/dt Internal protection External protection
1.5/0.9 1.5/0.9 0.6/0.6 –
3 4 5
Other characteristics Maximum response time at Ie Š 10 mA Maximum switching rate
0V1 1V0 At 55 °C ; at Ie: module alone duty cycle 40 % On resistive load duty cycle 50 %
Rated operating voltage Rated Insulation voltage for 1 minute
I/O Wired interface/earth (1) See temperature derating curves.
6 1 –
6 3 –
10 (50 Hz) ; 8 (60Hz) 10 (50 Hz) ; 8 (60Hz) AC13 0.6 0.7 AC14 0.6 0.7 AC15 0.6 0.7 50
6 7 8 9 10
67
Interfaces
References, curves
For discrete signals
Slim solid-state interface modules
Solid-state input modules Width
1
Input circuit Current Nominal voltage V 5 c 24 48 115…127 (50 Hz) a 120…127 (60 Hz) 230…240 (50 Hz) 230…240 (60 Hz)
Output circuit Current Nominal voltage V c 5…48 c 5…48 c 5…48 c 5…48 c 5…48 c 5…48 c 5…48
Sold in Unit lots of reference
17.5
c
Output circuit Current Nominal voltage A V c2 24…48 a 2.3 24…230 c3 24…48 a3 24…230
Sold in Unit lots of reference
mm 9.5
Input circuit Current Nominal voltage V 24 c
mm 9.5
2 Solid-state output modules Width
3 Accessories
4
24
ABS 2SC01EB d.c.
ABS 2SC01EB ABS 2SA01MB ABS 2SC02EB ABS 2SA02MB
ABS 2SC02EB d.c. Ie (A)
3
3
2
2
1/2
1
0
3/4
0
10
20
30
40
50 60 70 T °C ambient
ABS 2SA01MB a.c.
3 4
1
0
0
10
20
30
40
50 60 70 T °C ambient
ABS 2SA02MB a.c.
Ie (A)
7
Weight
Temperature derating curve for solid-state output modules Uc = Us = c 24 V
1/2
6
5 5 1 1
kg 0.029 0.029 0.029 0.032 0.032 0.033 0.033
ABS 2EC01EA ABS 2EC01EB ABS 2EC01EE ABS 2EA01EF ABS 2EA02EF ABS 2EA01EM ABS 2EA02EM
For connecting commons, use ABF C08ppp flexible combs (Please consult your customer care centre).
Ie (A)
5
5 5 5 5 5 5 5
Weight
3
3
2
2
Ie (A)
1/2 3
1/2
4 1
1
3/4
8
0
0
10
20
30
40
50 60 70 T °C ambient
0
0
10
20
30
40
50 60 70 T °C ambient
1 Vertical module alone or adjacent to modules with low heat dissipation.
2 Horizontal module alone or adjacent to modules with low heat dissipation.
3 Vertical module mounted with 2 modules with identical heat dissipation on both sides.
4 Horizontal module mounted with 2 modules with identical heat dissipation on both sides.
Presentation: page 64
Curves: page 68
9 10
68
Characteristics: page 65
References: page 68
Dimensions, schemes: page 69
kg 0.034 0.034 0.043 0.044
Interfaces
Dimensions, schemes
For discrete signals
Slim solid-state interface modules
Dimensions
ABS 2Sp02pp
74
1
74
ABS 2E/ABS 2Sp01pp
78
78
9,5
70,5
70,5
75
75
2
17,5
Circuit diagrams
3
Solid-state input modules
–
5…48 V
4 5 6
–
+
A2
A1
A2
A1
–A2
+A1
13
14
+
ABS 2Epppp
–14
ABS 2EApppp
+13
–14
+13
ABS 2Eppp
Solid-state output modules 5-24 V
+
+
–
–
5-24 V
5-24 V
+
–
+
5-24 V
A2
A1
A2
A1
A2
A1
A2
7 8 14
13
14
13
14
13
14
13
14
(1)
Resistive load
–F
9
–
+
(1) –F
–F
–
–F
+
13
–14
+13
ABS 2SA0pMB
–
ABS 2SC0pEB
A1
–A2
ABS 2SA0pMB
+A1
–A2
+A1
ABS 2SC0pEB
Inductive load
Resistive load
Inductive load
F: fuse DF1 SS133.2
10
(1) or peak limiter
69
Zelio Relay - Solid State Relays
Selection guide
SSR solid state relays
Applications
mounted
PF526060-24-Q
1 2 3 type
4 5 6 7
Control voltage ranges
a
90…280 V
c
3…32 V
Operating voltages
a
24…280 V, 48…530 V, 48…660 V
Type of switching
a
Zero voltage switching
Current
a
10, 25, 50, 75, 90, 125 A
Degree of protection
IP20
LED indication
Yes
Cooling
Thermal protection or with heat sink accessory
Solid state relay type
8
1 N/O SPST
Page
9 10
70
SSR P 76
1
PF526062-32-Q
PF526339-18-Q
5 rail mounted
2 3 1 N/O SPST 90…280 V
90…140 V
4…32 V
3…32 V
4
24…280 V
5
Zero voltage switching
10, 20, 30 A
45 A
6
IP20
Yes
7
Built-in heat sink
SSR D
8
76
9 10
71
Zelio Relay - Solid State Relays
Presentation
SSR solid state relays
Presentation
The SSR solid state relay range comprises: b relays for mounting: SSR P. b relays for 5 rail mounting: SSR D.
1
Description
1
2
2 3 5
SSR P relays for mounting 1 2 x Ø 4.5 holes for fixing. 2 Connection terminals. 3 Connection terminal screws. 4 Input indicator LED, green. 5 Thermal interface which must be via the back of the product.
4
3
1
1
4
2 3 4 6
SSR D relays for 5 rail mounting 1 Lugs for mounting. 2 Integrated heat sink. 3 Connection terminals. 4 Connection terminal screws. 5 Input indicator LED, green. 6 Bracket for mounting on 5 rail.
5
5 1
6 7 8 9 10 Presentation : page 72
72
Characteristics : page 73
References : page 76
Dimensions : page 77
Characteristics
Zelio Relay - Solid State Relays SSR P solid state relays mounting
General characteristics
Product certifications
UL E258297, CSA 168986
Product marking Ambient air temperature around the device
°C
- 40…+ 80
Storage
°C
- 40…+ 125
Encapsulation
Thermally conductive epoxy
Degree of protection
IP20
Terminal screw torque Relay type
1
e, IEC 60950 Operation
Nm SCR output, Zero voltage switching
Inputs: 1.1 Outputs: 2.2 SSR PCDS10A1
SSR PCDS25A1
SSR PCDS50A1
2
Input specification Control voltage range
cV
3…32
3…32
3…32
Minimum turn-on voltage
cV
3
3
3
Maximum turn-off voltage
cV
1.0
1.0
1.0
Typical input current
mA
10 at c 12 V
10 at c 12 V
10 at c 12 V
3
Output specification Operating voltage
aV
24…280
24…280
24…280
Load current range
A
0.15 …10
0.15…25
0.15…50
Transient overvoltage
Vpk
600
600
600
Maximum surge current (16.6 ms)
Apk
120
250
625
Maximum On-state voltage drop at rated current
Vpk
1.6
1.6
1.6
Thermal resistance junction to case
°C/W
1.48
1.02
0.63
Maximum I²t for fusing (8.3 ms)
A²sec
60
260
1620
Maximum off-state leakage current at rated voltage
mA
1.0
1.0
1.0
Minimum off-sate dv/dt at maximum rated voltage
V/µsec 500
500
500
Maximum turn-on time
Cycle
1/2
1/2
1/2
Maximum turn-off time
Cycle
1/2
1/2
1/2
SSR PCDS75A2
SSR PCDS90A3
SSR PCDS125A3
Relay type
SCR output, Zero voltage switching
4 5
Input specification Control voltage range
cV
4…32
4…32
4…32
Minimum turn-on voltage
cV
4
4
4
Maximum turn-off voltage
cV
1.0
1.0
1.0
Typical input current
mA
15 at c 5 V
15 at c 5 V
15 at c 5 V
Operating voltage
aV
48…530
48…660
48…660
Load current range
A
0.15…75
0.15…90
0.15…125
Transient overvoltage
Vpk
1200
1200
1200
Maximum surge current (16.6 ms)
Apk
1000
1200
1750
Maximum On-state voltage drop at rated current
Vpk
1.6
1.6
1.7
Thermal resistance junction to case
°C/W
0.31
0.28
0.22
Maximum I²t for fusing (8.3 ms)
A²sec
4150
6000
12 700
Maximum off-state leakage current at rated voltage
mA
10
1.0
1.0
Minimum off-sate dv/dt at maximum rated voltage
V/µsec 500
500
500
Maximum turn-on time
Cycle
1/2
1/2
1/2
Maximum turn-off time
Cycle
1/2
1/2
1/2
6
Output specification
7 8 9 10
73
Characteristics (continued)
Zelio Relay - Solid State Relays SSR P solid state relays mounting
Relay type
1 2 3 4 5 6
SCR output, Zero voltage switching
SSR PP8S10A1
SSR PP8S25A1
SSR PP8S50A1
Input specification Operating voltage
aV
90…280
90…280
90…280
Minimum turn-on voltage
Vrms
90
90
90
Maximum turn-off voltage
Vrms
10
10
10
Typical input current
mA
2 at 120 Vrms
2 at 120 Vrms
2 at 120 Vrms
Output specification Operating voltage
aV
24…280
24…280
24…280
Load current range
A
0.04…10
0.04…25
0.04…50
Transient overvoltage
Vpk
600
600
600
Maximum surge current (16.6 ms)
Apk
120
250
625
Maximum On-state voltage drop at rated current
Vpk
1.6
1.6
1.6
Thermal resistance junction to case
°C/W
1.48
1.02
0.63
Maximum I²t for fusing (8.3 ms)
A²sec
60
260
1620
Maximum off-state leakage current at rated voltage
mA
8…10
8…10
8…10
Minimum off-sate dv/dt at maximum rated voltage
V/µsec 500
500
500
Maximum turn-on time
Cycle
1/2
1/2
1/2
Maximum turn-off time
Cycle
1/2
1/2
1/2
SSR PP8S75A2
SSR PP8S90A3
SSR PP8S125A3
Relay type
SCR output, Zero voltage switching
Input specification Operating voltage
aV
90…280
90…280
90…280
Minimum turn-on voltage
Vrms
90
90
90
Maximum turn-off voltage
Vrms
10
10
10
Typical input current
mA
2 at 120 Vrms
2 at 120 Vrms
2 at 120 Vrms
Operating voltage
aV
80…530
48…660
48…660
Load current range
A
0.04…75
0.04…90
0.15…125
Transient overvoltage
Vpk
1200
1200
1200
Maximum surge current (16.6 ms)
Apk
1000
1200
1750
Maximum On-state voltage drop at rated current
Vpk
1.7
1.7
1.7
Thermal resistance junction to case
°C/W
0.31
0.28
0.22
Maximum I²t for fusing (8.3 ms)
A²sec
4150
6000
12 700
Maximum off-state leakage current at rated voltage
mA
10
5
5
Minimum off-sate dv/dt at maximum rated voltage
V/µsec 500
500
500
Maximum turn-on time
Cycle
1/2
1/2
1/2
Maximum turn-off time
Cycle
1/2
1/2
1/2
Output specification
7 8 9 10 Presentation : page 72
74
Characteristics : page 73
References : page 76
Dimensions : page 77
Characteristics
Zelio Relay - Solid State Relays SSR D solid state relay 5 rail mounting
General characteristics
Product certifications
UL E258297, CSA 168986
Product marking Ambient air temperature around the device
°C
Storage
°C
Encapsulation
Relay type
- 40…+ 80 - 40…+ 125 Thermally conductive epoxy
Degree of protection Terminal screw torque
1
e, IEC 60950 Operation
IP20 10…30 A relays
Nm
Inputs: 0.6…0.7 Outputs: 0.6…0.7
45 A relays
Nm
Inputs: 0.6…0.7 Outputs: 1.1…1.7
SCR output, Zero voltage switching
2
SSR DP8S10A1
SSR DP8S20A1
SSR DP8S30A1
SSR DF8S45A1
Input specification Operating voltage
aV
90…280
90…280
90…280
90…140
Minimum turn-on voltage
Vrms
90
90
90
90
Maximum turn-off voltage
Vrms
10
10
10
10
Typical input current
mA
2 (120 Vrms), 4 (240 Vrms)
2 (120 Vrms), 4 (240 Vrms)
2 (120 Vrms), 4 (240 Vrms)
15 (120 Vrms)
Operating voltage
aV
24…280
24…280
24…280
24…280
Load current range
A
0.15…10
0.15…20
0.15…30
0.15…45
Transient overvoltage
Vpk
600
600
600
600
Maximum surge current (16.6 ms)
Apk
120
250
625
625
Maximum On-state voltage drop at rated current
Vpk
1.6
1.6
1.6
1.6
Maximum I²t for fusing (8.3 ms)
A²sec
60
260
1620
1620
Maximum off-state leakage current at rated voltage
mA
10
10
10
10
Minimum off-sate dv/dt at maximum rated voltage
V/µsec 500
500
500
500
Maximum turn-on time
Cycle
1/2
1/2
1/2
1/2
Maximum turn-off time
Cycle
1/2
1/2
1/2
1/2
SSR DCDS10A1
SSR DCDS20A1
SSR DCDS30A1
SSR DCDS45A1
3
Output specification
Relay type
SCR output, Zero voltage switching
4 5
Input specification Control voltage range
cV
4…32
4…32
4…32
3…32
Minimum turn-on voltage
cV
4.0
4.0
4.0
4.0
Maximum turn-off voltage
cV
1.0
1.0
1.0
1.0
Typical input current
mA
8…12
8…12
8…12
17
Operating voltage
aV
24…280
24…280
24…280
24…280
Load current range
A
0.15…10
0.15…20
0.15…30
0.15…45
Transient overvoltage
Vpk
600
600
600
600
Maximum surge current (16.6 ms)
Apk
120
250
625
625
Maximum On-state voltage drop at rated current
Vpk
1.6
1.6
1.6
1.6
Maximum I²t for fusing (8.3 ms)
A²sec
60
260
1620
1620
Maximum off-state leakage current at rated voltage
mA
10
10
10
10
Minimum off-sate dv/dt at maximum rated voltage
V/µsec 500
500
500
500
Maximum turn-on time
Cycle
1/2
1/2
1/2
1/2
Maximum turn-off time
Cycle
1/2
1/2
1/2
1/2
6
Output specification
7 8 9 10
75
Zelio Relay - Solid State Relays
References
SSR solid state relays
Solid state relays, 1 N/O SPST b mounting
PF526060-24-Q
1
Switching
Voltage range Input
Output
Load current range
References
Weight
V
V
A
c 3…32
a 24…280
10
SSR PCDS10A1
0.113
25
SSR PCDS25A1
0.113
50
SSR PCDS50A1
0.113
a 48…530
75
SSR PCDS75A2
0.113
a 48…660
90
SSR PCDS90A3
0.113
125
SSR PCDS125A3
0.113
10
SSR PP8S10A1
0.113
25
SSR PP8S25A1
0.113
50
SSR PP8S10A1
0.113
a 80…530
75
SSR PP8S75A2
0.113
a 48…660
90
SSR PP8S90A3
0.113
125
SSR PP8S125A3
0.113
10
SSR DP8S10A1
0.272
20
SSR DP8S20A1
0.272
30
SSR DP8S30A1
0.272
kg
SCR output Zero voltage switching
2
c 4…32
PF526339-18-Q
3
SSR PCDS25A1
a 90…280
4 SSR DCDS10A1
b 5 rail mounting
PF526062-32-Q
5
SCR output Zero voltage switching
6 7
a 90…280
a 24…280
45
SSR DF8S45A1
0.482
c 4…32
a 24…280
10
SSR DCDS10A1
0.272
20
SSR DCDS20A1
0.272
30
SSR DCDS30A1
0.272
45
SSR DCDS45A1
0.482
SSR DCDS45A1
PF526063-50-Q
a 24…280
Accessories for mounted relays Description
For use with relays
Unit references
Heat sink
SSR PP8Spppp, SSR PCDSpppp
SSR AH1
0.487
Thermal interface Sold in lots of 10
SSR PP8Spppp, SSR PCDSpppp
SSR AT1
0.011
PF526064-28-Q
SSR AH1
9
a 24…280
a 90…140
c 3…32
8
a 24…280
10 SSR AT1 Presentation : page 72
76
Characteristics : page 73
References : page 76
Dimensions : page 77
Weight kg
Zelio Relay - Solid State Relays
Dimensions
SSR solid state relays
Solid state relays, 1 N/O SPST b mounting
Solid state relays SSR P
=
47,7 55,1
58,4
Ø4,5
47,3 35,5
1
Thermal interface SSR AT1 45,5
2
4,6
=
42,4
47,1
3 66
Heat sink SSR AH1
4 4,6
115,8
4,6 114,3
120,6
139,7
5
b 5 rail mounting 10…30 A relays
45 A relays Ø4,4
Ø4,4
87,4
76,2
98,8
80
89,7
98,8
6 (1)
11,2
(1)
13,15
22,5
7 22,6 45,5
8
97,7 106,7 (1) Ø 4.4 x 5.5 elongated hole
(1) Ø 4.4 x 5.5 elongated hole
9 10
77
Schneider Electric
products provide quality solutions, meeting all your Automation and Control applications requirements.
HMIs
Software tools Motion control
Networks & Communication
Interfaces & I/O
Automation
Detection
Motor control
Power supplies Mounting systems
A worldwide presence • More than 5,000 points of sale in 130 countries. • A range of products that meet the standards of the country in which they will be used.
Canadian • Over 100 dedicated sales engineers operate from multiple regional sales and technical service centres accross Canada. • Our sales engineers are skilled at assessing individual requirements. Combined with the expert of our product specialists, they will develop the most effective and economical solution for you, taking relevant regulations and standards into .
© 2009 Schneider Canada Inc. All Rights Reserved.
www.schneider-electric.ca Customer Service: (800) 565-6699
Schneider Electric 19 Waterman Av Toronto, Ontario M4B 1Y2 S8009CT0901EP R0
September 2009