Customer Item number Service Flowserve reference Date
: : : : :
CEPCOLSA CCS-P-3702 A/B Continuo 115701 Version 1 April 30, 2013
Pump size & type Based on curve no. Number of stages
: 2K4x3-13RV M3 ST : MIII7500BV : 1
Capacity Head Specific gravity Pump speed Test tolerance
: : : : :
401.0 USgpm 143.50 ft 1.000 1750 rpm Hydraulic Institute Level A
CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY. MCSF PROVIDES MECHANICAL PROTECTION ONLY. MINIMUM THERMAL FLOW MUST BE CALCULATED FOR THE SPECIFIC FLUID AND OPERATING CONDITIONS.
Copyright © 2009 Flowserve. All rights reserved.
FlowSelex v2.2
1 of 4
Hydraulic Datasheet Customer Customer reference Item number Service
: CEPCOLSA : : CCS-P-3702 A/B : Continuo
Pump / Stages Based on curve no. Flowserve reference Date
Operating Conditions Capacity Water capacity (CQ=1.00) Normal capacity Total Developed Head Water head (CH=1.00) NPSH available (NPSHa) NPSHa less NPSH margin Maximum suction pressure
: : : : : : : :
: : : :
2K4x3-13RV M3 ST MIII7500BV 115701 Version 1 April 30, 2013
/ 1
Materials / Specification
401.0 USgpm 143.50 ft 22.5 ft 4.3 psig
Material column code Pump specification
: D4... : ANSI B73.1 Other Requirements
Hydraulic selection : No specification Construction : No specification Test tolerance : Hydraulic Institute Level A Driver Sizing : Rated Power Seal configuration : Single Seal
Liquid Liquid type Temperature / Spec. Gravity Solid Size - Actual / Limit Viscosity / Vapor pressure
: : : :
Other 160 F 0.6
/ 1.000 / / 4.74 psia Performance
Hydraulic power Pump speed Efficiency (CE=1.00)
: 14.5 hp : 1750 rpm : 62.6 %
NPSH required (NPSHr) : 5.2 ft Rated power : 23.2 hp Maximum power : 33.2 hp Driver power : 30.0 hp / 22.4 kW Casing working pressure : 67.7 psig (based on shut off and Rated specific gravity @ Cut dia) Maximum allowable : 251.0 psig Hydrostatic test pressure : 413.0 psig Est. rated seal chamb. press. : -
Impeller diameter Rated Maximum Minimum Suction specific speed Minimum continuous flow Maximum head @ rated dia Flow at BEP Flow as % of BEP Efficiency at normal flow Impeller dia ratio (rated/max) Head rise to shut off Total head ratio (rated/max)
: : : : : : : : : : : :
12.19 in 13.00 in 9.50 in 7980 US units 130.7 USgpm 146.42 ft 571.1 USgpm 70.2 % 93.8 % 2.0 % 83.3 %
CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS; CAPACITY, HEAD, AND EFFICIENCY. MCSF PROVIDES MECHANICAL PROTECTION ONLY. MINIMUM THERMAL FLOW MUST BE CALCULATED FOR THE SPECIFIC FLUID AND OPERATING CONDITIONS.
Copyright © 2009 Flowserve. All rights reserved.
FlowSelex v2.2
2 of 4
Construction Datasheet Customer Customer reference Item number Service
: CEPCOLSA : : CCS-P-3702 A/B : Continuo
Pump / Stages Based on curve no. Flowserve reference Date
: : : :
2K4x3-13RV M3 ST MIII7500BV 115701 Version 1 April 30, 2013
Construction Nozzles Suction Discharge
Size 4.00 3.00
Rating 150# 150#
Casing mounting Casing split Impeller type Bearing type (radial) Bearing number (radial) Bearing type (thrust) Bearing number (thrust) Bearing lubrication Rotation (view from lg)
: : : : : : : : :
Casing Impeller Seal chamber Shaft Sleeve
: : : : :
Face RF RF
Foot Radial Rev Sgl Row 6310-C3 Dbl Row 5310-AHC3 Flood CW per Hyd. Institute Materials 316SS (D4/CF8M) 316SS (D4/CF-8M) FML Box / (316SS) ZH/316SS ButtWelded No Sleeve
Baseplate, Coupling and Guard Baseplate type Baseplate material Baseplate size Coupling manufacturer Coupling size Coupling / Shaft guard Shaft / seal guard
: : : : : : :
Type A Founda Steel 258 Baseplate Rexnord Omega ES20 Aluminum (Non-Spark) None Supplied
Pos'n End Top
Manufacturer Power Service factor (req'st / act) Speed Orientation / Mounting Driver Type Frame-size / material Enclosure Hazardous area class Explosion 'T' rating Volts / Phase / Hz Amps-full load/locked rotor Motor starting Insulation Temperature rise Bearings Lubrication Motor mounted by
: : : :
281.0 lb 234.0 lb 455.0 lb 1115.5 lb
/ 36510 cu.in
: Non witnessed : None : None Paint and Package
Pump paint Base grout surface prep Shipment type
: 70.0 : Seal Information
Arrangement Size Manufacturer / Type Material code (Man'f/API) Internal neck bushing
: : : : :
Sgl Int O-Ring 1.875 Flowserve CSX----ECXVNot Available
/ ISC Pusher / BSTFN
Gland
Testing Hydrostatic test Performance test NPSH test
Driver Information : USEM : 30.0 hp / 22.4 kW : 1.15 /: 1800 : / Foot : NEMA : 286T / CAST IRON : TEFC-841 : : : 460 V /3 / 60 : 35.20 A / 211.00 A : : F : : Ball : Grease : Flowserve
Sound Pressure (dBA @ 1.0 m) Driver, expected Pump & driver, estimated
Weights (Approx.) Bareshaft pump(nett) Baseplate(nett) Driver(nett) Shipping gross weight/vol.
/ 1
: Std.Polyurethane : Standard : Export
Gland material Flush Vent Drain Auxiliary seal device
: : : : :
Seal flush plan Seal flush construction Seal flush material Aux seal flush plan Aux seal flush construction Aux seal flush material
: : : : : :
316SS .375" NPT .375" NPT .375" NPT Carbon Bushing
Piping None None -
Notes Mark 3A w/Watchdog oiler Casing w/1/2" Plugged Drain (NPT) -
Copyright © 2009 Flowserve. All rights reserved.
FlowSelex v2.2
3 of 4
Full Page GA Drawing
All dimensions are in inches unless otherwise specified Customer
: CEPCOLSA
Pump size & type
: 2K4x3-13RV M3 ST
Drawing number
: -
Item number
: CCS-P-3702 A/B
Pump speed / Stages
: 1750 rpm / 1
Date
: April 30, 2013
Service
: Continuo
Flow / Head
: 401.0 USgpm / 143.50 ft
Certified by / Date :
: -
Customer PO #
: -
Driver power / Frame
: 30.0 hp / 22.4 kW / 286T
Seal type
: ISC Pusher
Flowserve reference
: 115701 Version 1
Volts / Phase / Hz
: 460 / 3 / 60
Seal flush plan
: None
Copyright © 2009 Flowserve. All rights reserved.
FlowSelex v2.2
4 of 4