How and in which S7 stations you can use the serial communication moduls?
U
Engineering Station Module System S7-300/S7-400 U STEP 7 V5.5 ET 200SP CM PtP ET 200MP CM PtP RS232 BA CM PtP RS232 HF CM PtP RS422/485 BA CM PtP RS422/485 HF TIA-Portal ET 200SP CM PtP ET 200MP CM PtP RS232 BA CM PtP RS232 HF CM PtP RS422/485 BA CM PtP RS422/485 HF S7-1500 U TIA-Portal S7-1500 CM PtP RS232 BA CM PtP RS232 HF CM PtP RS422/485 BA CM PtP RS422/485 HF ET 200MP CM PtP RS232 BA CM PtP RS232 HF CM PtP RS422/485 BA CM PtP RS422/485 HF ET 200SP CM PtP S7-1200 U
TIA-Portal
Order number
Interface
Manual
6ES7137-6AA00-0BA0 6ES7540-1AD00-0AA0 6ES7540-1AB00-0AA0 6ES7541-1AD00-0AB0 6ES7541-1AB00-0AB0 6ES7137-6AA00-0BA0 6ES7540-1AD00-0AA0 6ES7540-1AB00-0AA0 6ES7541-1AD00-0AB0 6ES7541-1AB00-0AB0 6ES7540-1AD00-0AA0 6ES7540-1AB00-0AA0 6ES7541-1AD00-0AB0 6ES7541-1AB00-0AB0 6ES7540-1AD00-0AA0 6ES7540-1AB00-0AA0 6ES7541-1AD00-0AB0 6ES7541-1AB00-0AB0 6ES7137-6AA00-0BA0
RS232 und RS422/RS485 RS232 RS232 RS422/RS485 RS422/RS485 RS232 und RS422/RS485 RS232 RS232 RS422/RS485 RS422/RS485 RS232 RS232 RS422/RS485 RS422/RS485 RS232 RS232 RS422/RS485 RS422/RS485 RS232 und RS422/RS485
69124220 69124220
ET 200MP CM PtP RS232 BA CM PtP RS232 HF CM PtP RS422/485 BA CM PtP RS422/485 HF ET 200SP CM PtP
6ES7540-1AD00-0AA0 6ES7540-1AB00-0AA0 6ES7541-1AD00-0AB0 6ES7541-1AB00-0AB0 6ES7137-6AA00-0BA0
RS232 RS232 RS422/RS485 RS422/RS485 RS232 und RS422/RS485
S7-1200
CM 1241 RS232
6ES7241-1AH32-0XB0
RS232
CM 1241 RS422/485 CB 1241 RS485 CM PtP CM PtP CM PtP RS232 BA CM PtP RS232 HF CM PtP RS422/485 BA CM PtP RS422/485 HF CM PtP RS232 BA CM PtP RS232 HF CM PtP RS422/485 BA CM PtP RS422/485 HF
6ES7241-1CH32-0XB0 RS422/RS485 6ES7241-1CH30-1XB0 RS485 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 6ES7137-6AA00-0BA0 RS232 und RS422/RS485 6ES7540-1AD00-0AA0 RS232 6ES7540-1AB00-0AA0 RS232 6ES7541-1AD00-0AB0 RS422/RS485 6ES7541-1AB00-0AB0 RS422/RS485 6ES7540-1AD00-0AA0 RS232 6ES7540-1AB00-0AA0 RS232 6ES7541-1AD00-0AB0 RS422/RS485 6ES7541-1AB00-0AB0 RS422/RS485
External U External U External U
GSDML GSD GSDML
ET 200SP ET 200SP ET 200MP
External U
GSD
ET 200MP
Bus System
Entry-ID: 109477693
Specific Feature
PN, DP PN, DP
HSP0240 necessary PN: GSD necessary DP: GSD necessary, Parametrization via FBs
59057093 (analogous use) PN, DP
Input parameter "Port" of the FBs is the input address
59057093
zentral
59057093
PN, DP
59057093 59057093
PN, DP, central For ET 200SP PC and central installation FW V1.0.2 is necessary PN, DP
59057093
PN, DP
You need S7-1200 with firmware V4.1 and the blocks of the library for S7-1200 ≥ V4.1 to use the ET 200SP CM PtP on S7-1200.
107623221
central
If you use the CM 1241 on a S7-1200 V4.1, you need the CM 1241 with firmware V2.1 and the blocks of the library for S7-1200 ≥ V4.1.
107623221 107623221 59062563 59062563 59062563
central central PN DP PN
FB created by according to manual FB created by according to manual FB created by according to manual
59062563
DP
FB created by according to manual
Note 1. For S7-1200 U with firmware V4.1 you can use the blocks of the library for S7-1200 ≥ V4.1. 2. You should always use the newest version of the function blocks.
Changedate: 08/09/2019
This entry is from the Service&Pupport portal of Siemens AG, Siemens Industry Online . The general of use (http://www.siemens.com/_of_use) apply.
Page: 1/2
s
How and in which S7 stations you can use the serial communication moduls?
Block Library 75226762 75226762
in TIA-Portal included in "Instructions" task card under: - Communication > Communication processor > PtP Communication - Communication > Communication processor > USS Communication - Communication > Communication processor > MODBUS (RTU) in TIA-Portal included in "Instructions" task card under: - Communication > Communication processor > PtP Communication - Communication > Communication processor > USS Communication - Communication > Communication processor > MODBUS (RTU)
for S7-1200 ≥ Firmware V4.1 in TIA-Portal included in "Instructions" task card under: - Communication > Communication processor > PtP Communication - Communication > Communication processor > USS Communication - Communication > Communication processor > MODBUS (RTU) for S7-1200 < Firmware V4.1 in TIA-Portal included in "Instructions" task card under: - Communication > Communication processor > Point-to-point - Communication > Communication processor > USS - Communication > Communication processor > MODBUS
Freeport / 3964(R) USS Modbus RTU ASCII yes yes yes, via FB yes yes yes yes, via FB no yes no yes yes yes yes, via FB yes yes yes yes, via FB no yes no yes yes yes yes, via FB no yes no yes yes yes yes, via FB no yes no yes yes yes yes, via FB yes yes
yes
yes, via FB
yes
yes
yes, via FB
no yes no yes yes
yes
no
yes
yes
Created by Created by Created by
yes yes yes yes yes
no no yes yes yes
yes yes no no no
yes yes no no no
Created by
yes
yes
no
no
Changedate: 08/09/2019
Entry-ID: 109477693